19
High-Performance Distance Sensor
Note: The menu item is only present for the Sensors Y1TA100QXVT80, Y1TA100QXT3 and OY1TA603P0003 if
pin function “Analog” is set.
Designation
Function
Key designation
Mode U/I
Analog output as current or voltage output
U
I
The analog output can be set up as either a current or a voltage output by pressing the
U or the I key.
The corresponding symbol is displayed.
Teach
Teach in the distances which correspond to the
upper and lower voltage values
10 V
respectively
20 mA
0 V
respectively
4 mA
The momentary actual distance is assigned to a voltage value of
10 V or a current value of 20 mA by
pressing the 10 V or the 20 mA key.
The momentary actual distance is assigned to a voltage value of
0 V or a current value of 4 mA by
pressing the 0 V or the 4 mA key.
If necessary, the assigned distances can be readjusted with the help of menu items At
0 V or at 10 V.
at 0 V
Distance at 0 V
+
–
The distance assigned to either 0 V or 4 mA is adjusted by pressing the + or the – key.
at 10 V
Distance at 10 V
+
–
The distance assigned to either 10 V or 20 mA is adjusted by pressing the + or the – key.