Retro-Reflex Sensors for Clear Glass Recognition

3.  Technical Data

3.1 Technical Data

Order Number

Technical Data

P1NK

202

206

Optical Data

Range

2,600 mm

Reference reflector

RQ100BA

Clear glass recognition

yes

Switching hysteresis

< 5 % 

Light source

Red light

Polarization filter

yes

Service life (ambient temp. = +25° C)

100,000 h

Max. permissible ambient light 

10,000 Lux

Single-lens optics

yes

Spot diameter

See table 1

Smallest detectable part

See table 2

Electrical Data

Supply power

10…30 V DC

IO-Link supply voltage

18…30 V DC

Current consumption (operating voltage = 24 V)

< 20 mA

Switching frequency

2000 Hz

Switching frequency (speed mode)

3500 Hz

Response time

0,25 ms

Response time (speed mode)

0,14 ms

Temperature drift

< 5 % 

Temperature range

−40…60 °C

Switching output voltage drop

< 2 V

Switching output switching current

100 mA

Switching output residual current

< 50 µA

Short-circuit protection

yes

Reverse polarity protected

yes

Overload-proof

yes

Lockable

yes

Interface

IO-Link

IO-Link version

1.1

Protection class

III

Output 
function

PNP antivalent

×

NPN antivalent

×

Connection Diagram No.

215

213

Mechanical Data

Setting method

Potentiometer

Housing material

Plastic

Degree of protection

IP67/IP68

Connection

 Plug M12; 4-pin

Lens cover

PMMA

Technical Safety Data

MTTFd (EN ISO 13849-1)

2414 a

Summary of Contents for P1NK Series

Page 1: ...EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 25 07 2018 www wenglor com P1NKxxx Retro Reflex Sensors for Cl...

Page 2: ...class 6 3 Technical Data 7 3 1 Technical Data 7 3 1 1 Spot diameter 8 3 1 2 Smallest detectable part 8 3 1 3 Switching distance 8 3 2 Complementary Products 9 3 3 Layout 9 3 4 Control Panel 10 3 5 Sc...

Page 3: ...zed by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in...

Page 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charac...

Page 5: ...ct can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry P...

Page 6: ...uct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is imp...

Page 7: ...ption operating voltage 24 V 20 mA Switching frequency 2000 Hz Switching frequency speed mode 3500 Hz Response time 0 25 ms Response time speed mode 0 14 ms Temperature drift 5 Temperature range 40 60...

Page 8: ...nge Reflector Range RQ100BA 0 2 60 m RR21_M 0 0 65 m RE18040BA 0 1 50 m ZRME01B01 0 0 25 m RQ84BA 0 1 80 m ZRME03B01 0 1 10 m RR84BA 0 2 20 m ZRAE02B01 0 0 90 m RE9538BA 0 0 85 m ZRMR02K01 0 0 30 m RE...

Page 9: ...an provide you with suitable connection technology for your product Suitable mounting technology no 350 Suitable connection technology no 2 S02 IO Link master wTeach2 software DNNF005 3 3 Layout 1 Opt...

Page 10: ...case of damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken i...

Page 11: ...Input Ground for the Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Ground for the Synchronization...

Page 12: ...arning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreli...

Page 13: ...or Reflector Sensor Reflector Object Sensor Reflector Object Object Sensor Reflector Sensor Reflector Object Sensor Reflector Object Required action in case of fault NOTE Shut down the machine Analyze...

Page 14: ...settings are possible via the IO Link interface The IODD can be found at www wenglor com in the product s download area 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning...

Page 15: ...tage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 25 07 18 Initial version of the operating instructio...

Reviews: