17
8. Information on PROFINET
You can find the GSDML file for download at
www.wenglor.com
→
Product World
→
Product search
(Enter the product number).
8.1. Overview of Device Access Point (DAP)
Modul-ID:
0
Submodul: 0
Parameter:
Name
Data
Type
Byte
Offset
Bit
Offset
Bit
Length Default Value
Value
Range
Change-
able
Index
Length Description
Webserver
Access
BitArea 0
0
1
0: enabled
0…1
Yes
300
1 Byte 0: enabled
1: blocked
Button lock
BitArea 0
0
1
0: enabled
0…1
Yes
301
1 Byte 0: enabled
1: blocked
Rotate
display
BitArea 0
0
1
0: not rotated
0…1
Yes
302
1 Byte 0: not rotated
1: rotated
Display
Intensity
BitArea 0
0
3
4: Screensaver 0…4
Yes
303
1 Byte
0: Min
1: Normal
2: Max
3: Power saver
mode
4: Screensaver
Display
mode
BitArea 0
0
3
0: Process
0…3
Yes
304
1 Byte
0: Process
1: Analysis
2: Text
3: Network
Language
BitArea 0
0
3
1: English
0…4
Yes
305
1 Byte
0: Deutsch
1: English
2: Français
3: Español
4: Italiano
8.2. Overview of modules used in the DAP OY2TA104P0150P
Name
Cyclical Input
Parameter
Parameter Slot (pluggable)
Distance Value
Measured value, Status
Filter value, Laser ON OFF
1 (fix)
Status
Bit field
–
2 (fix)
Filter
Filter value
–
3 (pluggable)
Laser
Laser ON OFF
–
4 (pluggable)
Display text
Display text
–
5 (pluggable)
Offset
Offset Set
–
6 (pluggable)
The detailed structure of the modules is described in the following.