4.5.4. Two-point Teach-In

• Set rotary selector switch (07) to Teach
• Align the spot to object A
• Activate the plus button (24)  

è

 Plus button (24) lights up

• Align the spot to object B
• Activate the minus button (25) 

è

 Minus button (25) lights up

• Set rotary selector switch (07) to Run

fig. 10 Two-point Teach-In

Scanning and barrier mode

The Sensor automatically determines the ideal switching point between the incoming light signals from object 
A and object B. 

If the red LED (02) blinks after completion of two-point teach-in, the difference between the two incoming signals is too small.

4.6. External Teach-In

Initialisation

The desired teach-In process must be selected at the Sensor prior to external Teach-In.

External Normal Teach-In 

(see also fig. 5 and 6)
Initialise Normal Teach-In:  Set rotary selector switch to Teach, press the plus button twice, set rotary selector 

switch to Run)

• Set rotary selector switch (07) to Run
• Apply 10 V to 30 V to the Teach-In input (in relation to minus pole, for at least 0.3 sec) 

è

 Red LED (02) blinks

• Disconnect voltage from the Teach-In input 

è

 Teach-In process ensues 

è

 Red LED (02) stops blinking 

Summary of Contents for ODX202

Page 1: ...ODX202 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status 10 10 2016 EN...

Page 2: ...le 7 4 Adjustment 8 4 1 On Delay and Off Delay 8 4 2 Selecting normally closed or normally open function NC NO 9 4 3 Selecting PNP NPN Push Pull 9 4 4 Setting Switching Distance with the potentiometer...

Page 3: ...ts and can thus be recognized from greater distances In barrier operation the color of the object has no effect on the range 2 Safety Precautions This operating instruction is part of the product and...

Page 4: ...0 V T Teach Input 3 2 Housing Dimensions 1 Transmitter Diode 2 Receiver Diode 3 3 EC Declaration of Conformity The EC declaration of conformity can be found on our website at www wenglor com in downl...

Page 5: ...Reverse Polarity Protection yes Overload Protection yes Teach Mode NT MT ZT DT TP Adjustment Teach In Housing Plastic Full Encapsulation yes Degree of Protection IP65 Connection M8 1 Protection Class...

Page 6: ...Status Indicator 02 Contamination Warning 07 Selector Switch 24 Plus Button 25 Minus Button 3 9 Mounting Instructions All applicable electrical and mechanical regulations standards and safety precauti...

Page 7: ...ting of the Sensor 3 9 3 Connecting the plastic fibre optic cable Please cut the plastic fibre optic cable once before using with the SW cutting tool Open the mounting slide with a screwdriver see fig...

Page 8: ...ot lighted up not lighted up 2 blinks pause 2 blinks 200 ms not lighted up lighted up 20 blinks pause 20 blinks Adjusting On Delay Adjusting Off Delay Set rotary selector switch 07 to On Delay Set rot...

Page 9: ...t rotary selector switch 07 to Run 4 3 Selecting PNP NPN Push Pull Set rotary selector switch 07 to NC NO PNP NPN Activate the plus button 24 for 5 seconds Plus button 24 and Minus button 25 blink Rel...

Page 10: ...d Set rotary selector switch 07 to Run 4 5 Setting Switching Distance with the Teach In function The ideal Switching Distance for the object to be recognized is selected automatically with the Teach I...

Page 11: ...tton 25 lights up Activate the minus button 25 again Minus button 25 is no longer illuminated Set rotary selector switch 07 to Run If a second button operation does not take place within 40 seconds th...

Page 12: ...button 24 again The recording mode is ended Plus button 24 is no longer illuminated Set rotary selector switch 07 to Run The switching output is not active during Teach In fig 9 Dynamic Teach In Scan...

Page 13: ...red LED 02 blinks after completion of two point teach in the difference between the two incoming signals is too small 4 6 External Teach In Initialisation The desired teach In process must be selected...

Page 14: ...ig 9 Initialise dynamic Teach In Set rotary selector switch to Teach press and hold the plus button for 5 sec release the plus button set rotary selector switch to Run Set rotary selector switch 07 to...

Page 15: ...utton No button is lighted up Light pulse frequency is max 10 kHz Set rotary selector switch 07 to Run Select a Light pulse frequency Set rotary selector switch 07 to Power Save Activate the plus butt...

Page 16: ...istance possible Activate the minus button 25 The Switching Point is set to the minimal switching distance value possible 5 Maintenance Instructions This wenglor Sensor is maintenance free It is advis...

Reviews: