List of status bits:
Number Function
Description of when the bit is set
Measured value read-
out
1
General error
One of the following bits is set.
—
2
Distance to object too
small
The current measured value is below the
working range.
Measuring range lower
limit
3
Distance to object too
large
The current measured value is above the
working range.
Measuring range upper
limit
4
No signal
The sensor does not detect an object
within its working range.
Measuring range upper
limit
5
Signal too weak
Too little light is reflected back to the sen-
sor from the object (e.g. very dark surface).
The quality of the measured value is re-
duced as a result.
Current measured value
6
Signal too strong
Too much light is reflected back to the
sensor from the object (e.g. reflector) The
quality of the measured value is reduced
as a result.
Current measured value
7
Warm-up procedure
The sensor is currently in the warm-up
phase and the quality of the measured
value does not yet comply with the speci-
fied technical data. See page 5 below.
Current measured value
8
Temperature too high
The sensor is at the upper limit of its tem-
perature range. If temperature continues to
rise, the sensor may be destroyed.
Current measured value
9
Temperature too low
The sensor is at the lower limit of its tem-
perature range. If temperature continues to
drop, the sensor may be destroyed.
Current measured value
7.10. Network
Network
Settings of the Network Parameters
IP-Address
Subnet Mask
DHCP
Std Gateway
MAC Address
Net Reset
3
Back
7
Run
IP-Address:
Display of the set IP-Address
Subnet Mask:
Display of the set Subnet Mask
DHCP:
Display DHCP ON or DHCP OFF
Std Gateway:
Display of the set standard gateway
MAC Address:
Display of the default MAC Address
Net Reset:
Reset network settings to the default settings