BEFORE STARTING THE GENERATOR
1. Verify that the generator is outside on a dry, level sur-
face. Allow at least two feet of clearance on all sides of the
generator.
2. To maximize safety, check that the generator is properly
grounded (see “Ground the Generator”).
3. Check there is sufficient level of oil in the crankcase. Add
oil if necessary (see “Add/check Oil”).
4. Verify the fuel selection dial is turned to the desired fuel.
Turn the dial to the “GASOLINE” position for gasoline and
the “PROPANE” position for LPG. Check that there is ad-
equate supply of the selected fuel.
5. Make sure all electrical devices are unplugged from the
generator during ignition. Otherwise it will be difficult for
the engine to start.
STARTING THE GENERATOR
WARNING!
The LPG cylinder valve must be shut
OFF when using gasoline. The generator’s fuel valve
must be shut OFF when using LPG.
Fig. 11
Fig. 12
STARTING THE GENERATOR
NOTE:
Allow the engine to run for several minutes before attempting to connect any electrical devices. This allows
the generator to stabilize its speed and temperature. Follow the instructions in the next section for properly con-
necting your electrical devices.
NOTE:
In case you have had repeated failed attempts to start the engine, please consult the troubleshooting guide
before attempting to start the generator. If problems persist please call
1-847-429-9263
, M-F 8-5 CST.
1
20
Gas Operation Start Up:
1. Ground the generator.
2. Turn the fuel valve to the ON position.
3. Turn the fuel selector switch to GAS.
4. Move the choke lever (Fig. 12 - 1) to the START
position.
5. Pull the recoil 1-3 times to prime the engine.
6. Full the recoil to start the engine.
7. Move the choke lever to the RUN position.
8. Connect electrical devices.
LPG Operation Start Up:
1. Connect the LPG regulator hose to the tank and
inlet on the generator.
2. Turn the LPG tank valve to the ON position.
3. Ground the generator.
4. Turn the fuel valve to the OFF position.
5. Move the choke lever (Fig. 12 - 1) to the START
position.
6. Pull the recoil 1-3 times to prime the engine.
7. Move the choke lever to the RUN position.
8. Pull the recoil to start the engine.
9. Connect electrical devices.
Summary of Contents for DF430X