ELECTRICAL INFORMATION
VOLTAGE CONVERSION
This machine is prewired for operation on a 110V - 120V, 60Hz circuit, but can be converted to operate on a
properly-grounded, 220V - 240V, 60Hz AC circuit, rated for not less than 15 amps. The voltage conversion MUST
be performed by a licensed professional electrician according to the instructions here.
To perform the conversion, remove the existing plug, install a new plug, and rewire the motor according to the
wiring diagram provided below. The motor wiring is located in the junction box on the side of the motor.
To convert the machine:
1. Disconnect the machine from power.
2. Replace the NEMA 5-15P plug on the power cord with a NEMA 6-15P plug (not included).
3. Re-wire the motor as shown in the wiring diagram below.
4. Verify that all connections are correct and secure.
5. Connect the machine to a properly-wired NEMA 6-15R receptacle. DO NOT use an extension cord when the
machine is running off 220V - 240V power.
WIRING DIAGRAM
9
Wires 2 and 3 connected.W
ires 1 & 2 connected; wires 3 and 4 connected.