![Wen 56235iX Instruction Manual Download Page 30](http://html1.mh-extra.com/html/wen/56235ix/56235ix_instruction-manual_956374030.webp)
TROUBLESHOOTING GUIDE
WARNING!
Stop using the generator immediately if any of the following problems occur or risk serious
personal injury. If you have any questions, please contact customer service at
1-800-232-1195
(M-F 8-5 CST),
or email
.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Engine will not
start.
Engine switch is set to OFF.
Set engine switch to ON.
Choke is open.
Close the choke.
Engine is out of fuel.
Add fuel.
Engine is filled with con-
taminated or old fuel.
Drain the fuel in the tank. Fill with fresh fuel.
Spark plug is dirty.
Clean the spark plug.
Spark plug is broken.
Replace spark plug.
Oil level is low.
Add or replace oil. This generator is equipped with a low
oil sensor. The engine will not start unless the oil level is
sufficient.
Carburetor is air locked.
Shut off the fuel valve. Remove the nut from the bottom of
the carburetor. Take off the carburetor to allow it to reset.
Place the carburetor back and reinstall the nut.
Engine runs
but there is no
electrical output.
Circuit breaker has been
tripped due to overload.
Disconnect all the loads. Wait for two minutes and push the
circuit breaker to the ON position to reset it.
Bad connecting cords/wires. Check the power cords and extension cords. Do not use if
any cord is damaged. Replace damaged cords immediately.
Bad electrical device con-
nected to the generator.
Try connecting a different device.
Generator runs but
does not support all
electrical devices
connected.
Generator is overloaded.
Perform these steps:
1. Turn off all electrical devices.
2. Unplug all electrical devices.
3. Turn off generator.
4. Wait several minutes.
5. Restart generator.
6. Try connecting few electrical loads to the generator.
Short circuit in one of the
devices.
Try disconnecting any faulty or short-circuited electrical
loads.
The air filter is dirty.
Clean or replace the air filter element (see page 20).
Engine is
“Hunting” during
Operation (Engine
RPM is fluctuating).
1. The fuel isn’t running
through the fuel valve.
2. The air filter is clogged.
3. The muffler or spark ar-
restor is blocked
4. There is gunk in the car-
buretor preventing a consis-
tent fuel/air mixture.
Turn off the generator and wait for it to cool down. Per-
form the following steps:
1. Check if the fuel is properly and consistently going
through the fuel valve
2. Check for any blockage in the air filter. Check and clean
the air filter as necessary.
3. Check if the spark arrestor is blocked. Clean with metal
brush as necessary.
4. Use “Gunk remover” spray on the carburetor jets.
30
Summary of Contents for 56235iX
Page 31: ...WIRING DIAGRAM 31...
Page 36: ...EXPLODED VIEW PARTS LIST CONTROL PANEL 36...
Page 39: ...NOTES 39...