14
STARTING THE ENGINE
To start the generator, perform the following steps:
1. Make sure no electrical devices are connected to the generator. Such devices can make it difficult for the en-
gine to start.
2. Check that the generator is properly grounded (see Figure 3, “Ground the Generator”).
3. Check the oil and gas levels.
4. Turn the fuel valve to the “ON” position (Figure 4).
5. Pull the choke rod to the “Start” position.
6. Set the engine switch to the “ON” position.
7. Turn the engine switch to the “START” position for 2-3 seconds or until the engine starts. NOTE: If the en-
gine does not start after 2-3 seconds, release the switch from the start position. Keeping the switch in the START
position too long can damage the starter.
8. If engine fails to start, wait 10 seconds, then repeat step 7. NOTE: After repeated attempts to start the engine,
please consult the troubleshooting guide before attempting again. If problems persist please call (800) 232-1195
M-F 8-5 CST.
9. Once the engine has started. Slowly move the choke lever all the way to the “Run” position.
Allow the generator to run for several minutes before attempting to connect any electrical devices. This allows
the generator to stabilize its speed and temperature.
STARTING THE GENERATOR
Figure 4 - Fuel Valve