1.1.7 Protocol GORGI
Data scope: 1 Start bit
7 Data bit
1 Parity bit (even)
2 Stop bit
4.800 Baud
transmission once a second
Byte Mark
Description
1 STX
HEX02
Start of text
2 weekday
3 weekday
4 weekday
5 SPACE
HEX20
6 10d
Day ten
7 1d
Day one
8 /
HEX2F
9 10m
Month ten
10 1m
Month one
11 /
HEX2F
12 10y
Year ten
13 1y
Year one
14 SPACE
HEX20
15 SPACE
HEX20
16 10h
Hour ten
17 1h
Hour one
18 :
HEX3A
19 10m
Minute ten
20 1m
Minute one
21 :
HEX3A
22 10s
Second ten
23 1s
Second one
24 CR
HEX0D
Carriage return
25 NUL
HEX00