Owner’s Manual

WPW-4000

Installa

Ɵ

 on

MOVING THE UNIT

PLUGGING IN THE UNIT

Unlock the casters and push the unit using the side handles to a 

fl

 at, level surface and set the 

caster brakes to the locked posi  on.

Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are pres-
ent, wipe o

  with a clean, dry cloth.

Check the power cord, plug and prongs for damage or excess play.
If any damage or excess play is found, contact a quali

fi

 ed repair technician or a quali

fi

 ed electri-

cian to perform replacement or repair of the power cord, plug or prongs.

NOTE:

  Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign material. The 

unit is equipped with an approved NEMA plug con

fi

 gura  on. (WPW-4000: 5-15P) The ap-

propriate outlet must be used for each plug type.

WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION

Do not use the unit in explosive environments or in areas where 

fl

 ammable 

gas leakage may occur.

Do not use the unit in areas where it will be exposed to rain or water.

Do not use the unit in a corrosive atmosphere.

Do not use the unit above 18°C(64°F) ~  50°C(122°F).

Do not install the unit on uneven or sloping surface. The unit may roll or 

topple over even if the casters are set to the locked posi

Ɵ

 on.

If the power cord or plug is damaged, repair should only be performed by

quali

fi

 ed electrical personnel.

Do not connect / disconnect the power cord or a

Ʃ

 empt to operate bu

Ʃ

 ons 

with wet hands. This could result in electrical shock.

Summary of Contents for AMERICOOL

Page 1: ...t can be installed by connec ng water line easily without installa on of duct Automa c water adjust valve control condenser water flow rate according to inlet water temperature It helps to supply prop...

Page 2: ...ing for large areas where cooling of an en re area is not prac cal or possible Please read this manual before installing the WPW 4000 as it provides important informa on that should be followed during...

Page 3: ...PW 4000 0 56 0 84 1 36 Model No Se ng temperature Room cool mode F C Se ng temperature Spot cool mode F C WPW 4000 64 86 18 30 32 86 0 30 Model No Applica on Area Room cool mode m Refrigerant Type oz...

Page 4: ...unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alco hols pes cides gasoline etc 14 DO NOT use the plug to start and to stop the unit Always use the control p...

Page 5: ...24 If water supply volume is small the unit is not operated properly and main component can get damaged 25 Stop opera on immediately if abnormal noise or odor is no ced Contact a local service center...

Page 6: ...carton 2 Placetheairductassemblyonthetopfrontof unit 3 Usescrews enclosedinsideofboxwithcoolair ductassembly ontheunitasshowninFigure5 Figure 2 Front and Right Side View Figure 3 Back and Le Side View...

Page 7: ...Takeoutthehose2pcsfromtheaccessorybox INLETHOSEincludea3 4 hosebarbforconnec ngplumbing or boosterpump OUTLETHOSEisjusthose 2 Connecthoseandtheendofcouplerand eupbyhoseclampas showninFigure6 No ce Don...

Page 8: ...ny other foreign material The unit is equipped with an approved NEMA plug configura on WPW 4000 5 15P The ap propriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR INS...

Page 9: ...a on If Alarm oc curs compressor stops System opera on stops when ALARM light is ac vated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahrenheit In Room...

Page 10: ...r and war ranty period in the table below Also a ach your purchase receipt as proof of purchase to this instruc on manual for future reference To ensure your product is covered by warranty the complet...

Page 11: ...stop opera ng The evaporator fan will con nue to run for 3 minutes If the fault is rec fied within 3 minutes the unit will resume opera on If the fault persists for more than 3 minutes the evaporator...

Page 12: ...tlet temperature sensor has a loose or broken connec on Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet temperature sensor has a loose or broken connec on Contact a qual...

Page 13: ...Owner s Manual WPW 4000 Wiring Diagram Figure 12 Circuit Wiring Diagram POWER 1P AC 115V 1P AC 208 230V 115V 220V POWER DRAIN PUMP option FD FD FD TR...

Page 14: ...ed if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned o and on quickly 2 Wait 2 minutes a er unit is turned o before turning the unit...

Page 15: ...562 231 7175 Please have the following informa on available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purcha...

Page 16: ...vi modifica ons or altera ons to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installa on or service ix shipping damage to any units or spare parts d...

Reviews: