Weltem AMERICOOL Owner'S Manual Download Page 16

Owner’s Manual

WPW-4000

LIMITED WARRANTY

AmeriCool warrants all AmeriCool products to be free from defects in materials or workmanship, 
under normal use and service, for a period of 12 months from the date of purchase to the end 
user (original invoice must be provided).  AmeriCool further warrants that the compressor will be 
free from defects in materials and workmanship for 36 months from the date of purchase to the 
end user.

AmeriCool’s obliga  on under this warranty is limited to the repair or replacement at its op  on, 
of any part or parts, which, upon Ameriool’s examina  on are shown to be defec  ve, or at Ameri-
Cool’s op  on, the return of the purchase price to the purchaser.  
Correc  on of such defects by repair or replacement, or at AmeriCool’s op  on, the return of the 
purchase price shall cons  tute ful

fi

 llment of warranty obliga  ons to the purchaser.  This warranty 

does not cover defects or malfunc  ons which result from causes beyond AmeriCool’s control, 
including, without limita  on,(i) unusal physical or electrical stress:(ii) accident, neglect, abuse, 
misuse or other abnormal use; (iii) failure to perform rou  ne maintenance in accordance with 
AmeriCool’s recommended procedures; (iv)normal wear and tear; (v) repairs or a  empted repairs 
by an unauthorized person; (vi) modi

fi

 ca  ons or altera  ons to the Products; (vii) use with parts or 

devices not supplied or approved by AmeriCool (viii) improper installa  on or service; (ix) shipping 
damage to any units or spare parts during shipping. This includes and is not limited to compres-
sors, evaporators and  condenser coils. This warranty shall extend only to the original end-user and 
shall be void if any labels or other iden  fying marks permanently a

  xed to Products when shipped 

by AmeriCool are removed, altered, defaced or obliterated.

TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY, AS LIMITED HEREIN, SHALL BE IN LIEU OF 
AND EXCLUSIVE OF ALL OTHER  WARRANTIES, EITHER EXPRESSED OR IMPLIED, ON THE PART OF 
AMERICOOL INC., OR WELTEM CO.,LTD.  WHETHER ARISING FROM LAW, COURSE OF DEALING, US-
AGE OF TRADE, OR OTHERWISE, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF 
MERCHANT-ABILITY OR FITNESS OF A PARTICULAR PURP OSE OR ANY LIABILITY FOR COMMERCIAL 
LOSSES BASED UPON NEGLIGENCE OR MANUFACTURER’S STRICT LIABILITY. EXCEPT AS EXPRESSLY 
PROVIDED  HEREIN,NEITHER AMERICOOL, INC., NOR WELTEM CO., LTD. WILL, IN ANY EVENT, BE 
LIABLE  FOR LOST PROFITS, COSTS OF PROCESSING,INJURY, GOODWILL, OR  ANY OTHER CONSE-
QUENTIAL DAMAGES OF ANY KIND ARISING  FROM BREACH OF THIS  WARRANTY.

printed in April, 2013

Manufactured in Weltem Co., Ltd., 
973-5, Yangdeok-dong, Masanhoewon-gu, Changwon-City, Gyeongnam,
Republic of KOREA 630-728 www.weltem.com              
Distributed by Americool,Inc. In the USA (Tel.562-231-7175)
WWW.AMERICOOLINC.COM

Summary of Contents for AMERICOOL

Page 1: ...t can be installed by connec ng water line easily without installa on of duct Automa c water adjust valve control condenser water flow rate according to inlet water temperature It helps to supply prop...

Page 2: ...ing for large areas where cooling of an en re area is not prac cal or possible Please read this manual before installing the WPW 4000 as it provides important informa on that should be followed during...

Page 3: ...PW 4000 0 56 0 84 1 36 Model No Se ng temperature Room cool mode F C Se ng temperature Spot cool mode F C WPW 4000 64 86 18 30 32 86 0 30 Model No Applica on Area Room cool mode m Refrigerant Type oz...

Page 4: ...unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alco hols pes cides gasoline etc 14 DO NOT use the plug to start and to stop the unit Always use the control p...

Page 5: ...24 If water supply volume is small the unit is not operated properly and main component can get damaged 25 Stop opera on immediately if abnormal noise or odor is no ced Contact a local service center...

Page 6: ...carton 2 Placetheairductassemblyonthetopfrontof unit 3 Usescrews enclosedinsideofboxwithcoolair ductassembly ontheunitasshowninFigure5 Figure 2 Front and Right Side View Figure 3 Back and Le Side View...

Page 7: ...Takeoutthehose2pcsfromtheaccessorybox INLETHOSEincludea3 4 hosebarbforconnec ngplumbing or boosterpump OUTLETHOSEisjusthose 2 Connecthoseandtheendofcouplerand eupbyhoseclampas showninFigure6 No ce Don...

Page 8: ...ny other foreign material The unit is equipped with an approved NEMA plug configura on WPW 4000 5 15P The ap propriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR INS...

Page 9: ...a on If Alarm oc curs compressor stops System opera on stops when ALARM light is ac vated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahrenheit In Room...

Page 10: ...r and war ranty period in the table below Also a ach your purchase receipt as proof of purchase to this instruc on manual for future reference To ensure your product is covered by warranty the complet...

Page 11: ...stop opera ng The evaporator fan will con nue to run for 3 minutes If the fault is rec fied within 3 minutes the unit will resume opera on If the fault persists for more than 3 minutes the evaporator...

Page 12: ...tlet temperature sensor has a loose or broken connec on Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet temperature sensor has a loose or broken connec on Contact a qual...

Page 13: ...Owner s Manual WPW 4000 Wiring Diagram Figure 12 Circuit Wiring Diagram POWER 1P AC 115V 1P AC 208 230V 115V 220V POWER DRAIN PUMP option FD FD FD TR...

Page 14: ...ed if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned o and on quickly 2 Wait 2 minutes a er unit is turned o before turning the unit...

Page 15: ...562 231 7175 Please have the following informa on available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purcha...

Page 16: ...vi modifica ons or altera ons to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installa on or service ix shipping damage to any units or spare parts d...

Reviews: