Weltem AMERICOOL Owner'S Manual Download Page 1

Owner’s Manual

WPW-4000

Please read and save these instructions. Read carefully before attempting to assemble, install, oper-

ate or maintain the product described.

Protect yourself and others by observing all safety information. Failure to comply with instructions 

could result in personal injury and / or property damage! Retain instructions for future reference.

WELTEM Water-cooled Portable Air Condi  oner feature spot 
cooling for large areas where cooling of the en  re area is not 
prac  cal. A dedicated spot cooling thermostat controls the unit 
in this applica  on. 
Water-cooled air condi  oner does not discharge exhaust heat. 
So it can also be used for room cooling. And it is space-e

  cient 

because it doesn’t need to have hot air duct.
In addi  on, It can be installed by connec  ng water line easily 
without installa  on of duct.
Automa  c water adjust valve control condenser water 

fl

 ow rate 

according to inlet water temperature. It helps to supply proper 
condensing water to unit. 
A control panel provides ease of use and contains a self-diag-
nos  c func  on and display, showing opera  ng modes, room and set temperatures and faults. If an 
abnormal opera  on occurs, a visual display of the fault is shown. Caster wheels are included for easy 
portability. Water Hose kit of 25   is allows for convenient installa  on and portability. (Hose kit is sold 
separately.)  Suitable applica  ons include : a factory or work place, industrial kitchen, emergency cool-
ing etc,

A  er unpacking the unit, carefully inspect unit for any damage that may have occurred during 
transit. Check for any loose, missing, or damaged parts.

Descrip

Ɵ

 on

Unpacking

Owner’s Manual

WPW-4000

Water Cooled Portable air Conditioner

by

WPW-4000

Figure 1

Summary of Contents for AMERICOOL

Page 1: ...t can be installed by connec ng water line easily without installa on of duct Automa c water adjust valve control condenser water flow rate according to inlet water temperature It helps to supply prop...

Page 2: ...ing for large areas where cooling of an en re area is not prac cal or possible Please read this manual before installing the WPW 4000 as it provides important informa on that should be followed during...

Page 3: ...PW 4000 0 56 0 84 1 36 Model No Se ng temperature Room cool mode F C Se ng temperature Spot cool mode F C WPW 4000 64 86 18 30 32 86 0 30 Model No Applica on Area Room cool mode m Refrigerant Type oz...

Page 4: ...unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alco hols pes cides gasoline etc 14 DO NOT use the plug to start and to stop the unit Always use the control p...

Page 5: ...24 If water supply volume is small the unit is not operated properly and main component can get damaged 25 Stop opera on immediately if abnormal noise or odor is no ced Contact a local service center...

Page 6: ...carton 2 Placetheairductassemblyonthetopfrontof unit 3 Usescrews enclosedinsideofboxwithcoolair ductassembly ontheunitasshowninFigure5 Figure 2 Front and Right Side View Figure 3 Back and Le Side View...

Page 7: ...Takeoutthehose2pcsfromtheaccessorybox INLETHOSEincludea3 4 hosebarbforconnec ngplumbing or boosterpump OUTLETHOSEisjusthose 2 Connecthoseandtheendofcouplerand eupbyhoseclampas showninFigure6 No ce Don...

Page 8: ...ny other foreign material The unit is equipped with an approved NEMA plug configura on WPW 4000 5 15P The ap propriate outlet must be used for each plug type WARNINGS REGARDING PROPER LOCATION FOR INS...

Page 9: ...a on If Alarm oc curs compressor stops System opera on stops when ALARM light is ac vated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahrenheit In Room...

Page 10: ...r and war ranty period in the table below Also a ach your purchase receipt as proof of purchase to this instruc on manual for future reference To ensure your product is covered by warranty the complet...

Page 11: ...stop opera ng The evaporator fan will con nue to run for 3 minutes If the fault is rec fied within 3 minutes the unit will resume opera on If the fault persists for more than 3 minutes the evaporator...

Page 12: ...tlet temperature sensor has a loose or broken connec on Contact a qualified service agent Abnormal tempera ture sensor value TH2 Inlet temperature sensor has a loose or broken connec on Contact a qual...

Page 13: ...Owner s Manual WPW 4000 Wiring Diagram Figure 12 Circuit Wiring Diagram POWER 1P AC 115V 1P AC 208 230V 115V 220V POWER DRAIN PUMP option FD FD FD TR...

Page 14: ...ed if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned o and on quickly 2 Wait 2 minutes a er unit is turned o before turning the unit...

Page 15: ...562 231 7175 Please have the following informa on available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purcha...

Page 16: ...vi modifica ons or altera ons to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installa on or service ix shipping damage to any units or spare parts d...