Owner’s Manual

WPC-15000

Please read and save these instructions. Read carefully before attempting to assemble, install, oper-

ate or maintain the product described.

Protect yourself and others by observing all safety information. Failure to comply with instructions 

could result in personal injury and / or property damage! Retain instructions for future reference.

AmeriCool by Weltem Portable Air Condi  oners feature spot cool-
ing for large areas where cooling of the en  re area is not prac  cal. 
A dedicated spot cooling thermostat controls the unit in this ap-
plica  on. These air condi  oners can also be used in smaller areas 
for room cooling.
A control panel provides ease of use and contains a self-diagnos  c 
func  on and display, showing opera  ng modes, room and set 
temperatures, and faults. If an abnormal opera  on occurs, a visual 
display of the fault is shown. Caster wheels are included for easy 
portability. Suitable applica  ons include: a factory or work place, 
industrial kitchen, computer room, emergency cooling, outdoor 
event, etc.

A  er unpacking the unit, carefully inspect unit for any damage that may have occurred during 
transit. Check for any loose, missing, or damaged parts.

Descrip

Ɵ

 on

Unpacking

WPC-15000, WPC-15003

Figure 1

Owner’s Manual

Speci

fi

 ca

Ɵ

 ons

WPC-15000 / WPC-15003

Portable Air Conditioners

by

Model No.

Power Supply Ph-V-Hz

Cooling Capac-

ity Btu/h

Power Consump-

 on Wa  s

EER Btu/Wh

WPC-15000

Single Phase, 220V, 60Hz

60,000

5000

12.0

WPC-15003

3 phases, 460V, 60Hz

71,000

5400

13.2

Model No.

Nema Plug

Power Cord 

Gauge AWG

Power Cord Length 

 

Dimensions 

W x D x H - in. (mm)

WPC-15000

6-50 P

8

6

735 x 1310 x 1520

WPC-15003

Terminal type

10

6

Model No.

Weight (Net / Gross) Lbs(kg)

No. of Cool Air 

Outlets Pcs

Condensate tank 

Gallons(Liters)

Ambient temperature 

range  °F( °C)

WPC-15000

(661 / 694) 300 / 315

3

Auto Pump 

Included

64~113 (18~45)

WPC-15003

(694 / 727) 315 / 330

Summary of Contents for americool WPC-15000

Page 1: ...sual display of the fault is shown Caster wheels are included for easy portability Suitable applica ons include a factory or work place industrial kitchen computer room emergency cooling outdoor event...

Page 2: ...s inlet and outlet grilles 8 DO NOT use the unit in areas where it will be exposed to rain or water 9 NEVER unplug the unit while it is opera ng Model No Se ng temperature Room cool mode F C Se ng tem...

Page 3: ...rson must replace it in order to avoid a hazard or shock 19 The filters must be used with the product at all mes When the filters are removed for clean ing always ensure that the unit has been turned...

Page 4: ...sedinsideofbox withcoolairoutlethose s toinstall thecoolairoutlethose s ontheaircondi onerasshownin Figure5 1 Take out the cord holder from the accessory box 2 Placethecordholderon thebacksideofaircon...

Page 5: ...r prongs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or...

Page 6: ...m opera on If Alarm oc curs compressor stops System opera on stops when ALARM light is ac vated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahrenheit I...

Page 7: ...top of the filter in the guide and slide the filter up un l the bo om of the filter clears the frame Then push the bo om of filter into the guide and let filter gently fall inside the guide NOTE For...

Page 8: ...keep this manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is ac vated if abnormal opera on occurs and a code is displayed on t...

Page 9: ...kinked Do not use the air condi oner if ambient temperature is higher than 45 C 113 F Abnormal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connec on Contact a quali...

Page 10: ...Owner s Manual WPC 15000 WPC 15003 Wiring Diagram Figure 9 Circuit Wiring Diagram WPC 15000 TH1 TH2 TH3 RELAY RELAY TIMER TB N 1 DEALY 20 seconds DRAIN PUMP NO 1 COMP NO 2 COMP L 1 POWER 1P AC 208 23...

Page 11: ...3 POWER 3P AC 380V 50HZ 3P AC 460V 60HZ DRAIN PUMP R L1 S L2 T L3 C CM PHASE PROTECTOR 380 440V 220V TR MB MC1 OCR1 R S T R E S T R S T R S T R S T MC2 COM Comp Over Load H L OCR2 B NC A NO Wiring Dia...

Page 12: ...wer cord No cold air flows from the cold air outlet 1 Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit i...

Page 13: ...on vi modifications or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any units or spare pa...

Reviews: