MOVING THE UNIT

PLUGGING IN THE UNIT

Unlock the casters and push the unit using the side handles to a 

fl

 at, level surface and set the 

caster brakes to the locked posi  on.

Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are pres-
ent, wipe o

  with a clean, dry cloth.

Check the power cord, plug and prongs for damage or excess play.
If any damage or excess play is found, contact a quali

fi

 ed repair technician or a quali

fi

 ed electri-

cian to perform replacement or repair of the power cord, plug or prongs.

NOTE: Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign material.

WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION

Do not use the unit in explosive environments or in areas where 

fl

 ammable 

gas leakage may occur.

Do not use the unit in areas where it will be exposed to rain or water.

Do not use the unit in a corrosive atmosphere.

Do not use the unit above 18°C(64°F) ~ 45°C(113°F).

Do not install the unit on uneven or sloping surface. The unit may roll or 

topple over even if the casters are set to the locked posi

Ɵ

 on.

If the power cord or plug is damaged, repair should only be performed by

quali

fi

 ed electrical personnel.

Do not connect / disconnect the power cord or a

Ʃ

 empt to operate bu

Ʃ

 ons 

with wet hands. This could result in electrical shock.

Summary of Contents for americool WPC-15000

Page 1: ...sual display of the fault is shown Caster wheels are included for easy portability Suitable applica ons include a factory or work place industrial kitchen computer room emergency cooling outdoor event...

Page 2: ...s inlet and outlet grilles 8 DO NOT use the unit in areas where it will be exposed to rain or water 9 NEVER unplug the unit while it is opera ng Model No Se ng temperature Room cool mode F C Se ng tem...

Page 3: ...rson must replace it in order to avoid a hazard or shock 19 The filters must be used with the product at all mes When the filters are removed for clean ing always ensure that the unit has been turned...

Page 4: ...sedinsideofbox withcoolairoutlethose s toinstall thecoolairoutlethose s ontheaircondi onerasshownin Figure5 1 Take out the cord holder from the accessory box 2 Placethecordholderon thebacksideofaircon...

Page 5: ...r prongs NOTE Make sure the AC outlet is free of dirt dust oil water or any other foreign material WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION Do not use the unit in explosive environments or...

Page 6: ...m opera on If Alarm oc curs compressor stops System opera on stops when ALARM light is ac vated blinks longer than 3 minutes 7 CURRENT TEMP Displays current room temperature in display in Fahrenheit I...

Page 7: ...top of the filter in the guide and slide the filter up un l the bo om of the filter clears the frame Then push the bo om of filter into the guide and let filter gently fall inside the guide NOTE For...

Page 8: ...keep this manual for future reference and keep sales receipt as proof of purchase SELF DIAGNOSTIC CODES See Table 1 The alarm light is ac vated if abnormal opera on occurs and a code is displayed on t...

Page 9: ...kinked Do not use the air condi oner if ambient temperature is higher than 45 C 113 F Abnormal tempera ture sensor value TH1 Outlet tem perature sensor has a loose or broken connec on Contact a quali...

Page 10: ...Owner s Manual WPC 15000 WPC 15003 Wiring Diagram Figure 9 Circuit Wiring Diagram WPC 15000 TH1 TH2 TH3 RELAY RELAY TIMER TB N 1 DEALY 20 seconds DRAIN PUMP NO 1 COMP NO 2 COMP L 1 POWER 1P AC 208 23...

Page 11: ...3 POWER 3P AC 380V 50HZ 3P AC 460V 60HZ DRAIN PUMP R L1 S L2 T L3 C CM PHASE PROTECTOR 380 440V 220V TR MB MC1 OCR1 R S T R E S T R S T R S T R S T MC2 COM Comp Over Load H L OCR2 B NC A NO Wiring Dia...

Page 12: ...wer cord No cold air flows from the cold air outlet 1 Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit i...

Page 13: ...on vi modifications or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any units or spare pa...

Reviews: