background image

page 

31  

Owner’s Manual

HPC-3000 / WPC-4000 / HPC-5000 / WPC-7000 / WPC-9000 / WPC-15000

LIMITED WARRANTY

AMERICOOL ONE-YEAR LIMITED WARRANTY.

 AMERICOOL BY WELTEM

 

PORTABLE AIR 

CONDITIONERS,  MODELS  COVERED  IN  THIS  MANUAL,  ARE  WARRANTED  BY  AMERI-

COOL  TO  THE  ORIGINAL  USER  AGAINST  DEFECTS  IN  WORKMANSHIP  OR  MATERIALS 

UNDER NORMAL USE FOR ONE YEAR AFTER DATE OF PURCHASE. ANY PART WHICH IS 

DETERMINED TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP AND RETURNED TO 

AN AUTHORIZED SERVICE LOCATION, AMERICOOL DESIGNATES, SHIPPING COSTS PRE-

PAID,  WILL  BE,  AS  THE  EXCLUSIVE  REMEDY,  REPAIRED  OR  REPLACED  BY  AMERICOOL 

OPTION. FOR LIMITED WARRANTY CLAIM PROCEDURES, SEE “PROMPT DISPOSITION” 

BELOW. THIS LIMITED WARRANTY GIVE PURCHASERS SPECIFIC LEGAL RIGHTS WHICH 

VARY FROM JURISDICT-

ION TO JURISDICTION.

LIMITATION OF LIABILITY. 

TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, AMER-

ICOOL LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DIS-

CLAIMED. AMERICOOL LIABILITY IN ALL EVENTS IS LIMITED TO AND SHALL NOT EXCEED 

THE PURCHASE PRICE PAID.

WARRANTY  DISCLAIMER.

  A  DILIGENT  EFFORT  HAS  BEEN  MADE  TO  PROVIDE  PROD-

UCT INFORMATION AND ILLUSTRATE THE PRODUCTS IN THIS LITERATURE ACCURATELY; 

HOWEVER, SUCH INFORMATION AND ILLUSTRATIONS ARE FOR THE SOLE PURPOSE OF 

IDENTIFICATION, AND DO NOT EXPRESS OR IMPLY A WARRANTY THAT THE PRODUCTS 

ARE MERCHANTABLE, OR FIT FOR PARTICULAR PURPOSE, OR THAT THE PRODUCTS WILL 

NECESSARILY CONFORM TO THE ILLUSTRATIONS OR DESCRIPTIONS. EXCEPT AS PROVID-

ED BELOW, NO WARRANTY OF AFFIRMATION OF FACT, EXPRESSED OR IMPLIED, OTHER 

THAT  AS  STATED  IN  THE  “LIMITED  WARRANTY”  ABOVE  IS  MADE  OR  AUTHORIZED  BY 

AMERICOOL.

Technical Advice and Recommendations, Disclaimer. 

Notwithstanding any past practice 

or dealings or trade custom, sales shall not include the furnishing of technical advice or 

assistance or system design. Americool assumes no obligations or liability on account of 

any unauthorized recommendations, opinions or advice as to the choice, installation or 

use of products.

Product Suitability. 

Many jurisdictions have codes and regulations governing sales, con-

struction, installation, and/or use of products for certain purposes, which may vary from 

those in neighboring areas. While attempts are made to assure that Americool products 

comply with such codes, Americool cannot guarantee compliance, and cannot be re-

Summary of Contents for Americool HPC-3000

Page 1: ...ractical A dedicated spot cooling thermostat controls the unit in this application These air conditioners can also be used in smaller areas for room cooling A control panel provides ease of use and co...

Page 2: ...Power Cord Holder Discharge Ducts Supply Air Duct Exhaust Flange Optional Ambient Air Adapters Optional ASSEMBLY HPC 5000 9 Component Parts Power Cord Holder Rubber Stoppers Discharge Ducts Supply Ai...

Page 3: ...al lowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and service if it is required If you experience a problem with the unit...

Page 4: ...is User s Manual 6 DO NOT tilt the unit 7 DO NOT cover or obstruct the unit s inlet and or outlet grilles 8 DO NOT use the unit in areas where it will be exposed to rain or water 9 NEVER unplug the un...

Page 5: ...mes damaged a qualified service agent qualified electrician or similarly qualified person must replace it in order to avoid a hazard or shock 19 The filters must be used with the product at all times...

Page 6: ...d regulations Only qualified personnel should conduct these installations as failure to acknowledge electrical hazards could prove to be fatal AmeriCool by Weltem Portable Air Conditioners feature spo...

Page 7: ...et hose Display Control board Top fan wire grille Evaporator filter Guide bar for condensate water tank Condensate water tank Water level is sensed and the unit opera on is stopped when tank is full A...

Page 8: ...ox with cool air outlet hose s to install the cool air outlet hose s on the air condi oner as shown in Figure 11 An ambient air adapter can be purchased separately Air adapter fits over the condenser...

Page 9: ...the unit screws inside the accessory pack Figure 16 Rubber Stopper a achment An exhaust flange can be purchased separately Exhaust flange fits over the top exhaust fan duct improving cooling efficien...

Page 10: ...ange from carton 2 Place the top fan exhaust flange on the top of air condi oner 3 Use screws enclosed inside of box with the top fan exhaust flange to install the top fan exhaust flange on air condi...

Page 11: ...ure 22 3 Use screws enclosed inside of box with the top fan exhaust flange to install the top fan exhaust flange on air condi oner as shown in Figure 23 DISCHARGE DUCTS SUPPLY AIR DUCT AMBIENT AIR ADA...

Page 12: ...ERS Op onal Ambient air adapters can be purchased separately Air adapter fits over the condenser to duct condenser air to the unit to improve cooling efficiency 1 Remove air adapters from cartons 2 Pl...

Page 13: ...found contact a qualified repair technician or a qualified electrician to perform replacement of repair of the power cord plug or prongs NOTE Make sure the AC outlet is free of dirt dust oil water or...

Page 14: ...5 seconds after button is pressed Regulates temperature based on outlet cool air temperature 4 ROOM COOL BUTTON Activates compressor and produces cool air 5 seconds after button is pressed Regulates t...

Page 15: ...re displayed when abnormal operation occurs 8 TARGET TEMP Displays the unit set temperature for ROOM COOL mode only OFF TIMER Enter to Timer Setting Mode if you press BLOWER Button and SPOT COOL Butto...

Page 16: ...filters from the middle bar slightly and then angle the filter outwards from the bo om and remove Pull the filter frame forward to remove the front filter Slide filter up and use a vacuum cleaner to r...

Page 17: ...o clean the condenser filter lift up on the rear or side filter from the middle bar slightly and then angle the filter outwards from the bottom and remove 7 Use the same cleaning procedure as in steps...

Page 18: ...will resume operation If the fault persists for more than 3 minutes the evaporator fan also stops The fault must be rectified before the unit can resume normal operation TROUBLESHOOTING Spring Replace...

Page 19: ...pera ture is higher than 45 C 113 F Abnormal tempera ture sensor value TH1 Outlet tempera ture sensor has a loose or broken connection Contact a qualified service agent Abnormal tempera ture sensor va...

Page 20: ...ient air cannot be properly cooled if the filter is dirty and not regularly cleaned Compressor restart in 2 minutes after turning off to protect the compressor The ambient air tempera ture may be too...

Page 21: ...Flow Condenser CFM 610 1250 1120 857 Motor Input High Low Evaporator KW 0 091 0 089 0 36 0 26 0 24 0 20 Motor Input Condenser KW 0 08 0 26 Air Filter Aluminum Aluminum Vinyl chloride Aluminum Vinyl c...

Page 22: ...low Condenser CFM 1560 1660 3600 Motor Input High Low Evaporator KW 0 9 0 8 0 6 0 5 0 4 0 35 Motor Input Condenser KW 1 Air Filter Aluminium Vinyl chloride Aluminium Vinyl chloride Aluminium Vinyl chl...

Page 23: ...page 23 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000 Wiring Diagram TH1 TH2 TH3 DRAIN PUMP Figure 36 Circuit Wiring Diagram Models HPC 3000 HPC 5000 HPC 7000...

Page 24: ...page 24 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000 DRAIN PUMP option POWER 1P AC115 POWER 1P AC115 Figure 37 Circuit Wiring Diagram Models WPC 4000...

Page 25: ...page 25 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000 Figure 38 Circuit Wiring Diagram Models WPC 7000 WPC 9000 DRAIN PUMP option RELAY RELAY...

Page 26: ...page 26 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000 Figure 39 Circuit Wiring Diagram Models WPC 15000 Wiring Diagram...

Page 27: ...have the following informa tion available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purchased d All of the m...

Page 28: ...page 28 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000...

Page 29: ...page 29 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000...

Page 30: ...page 30 Owner s Manual HPC 3000 WPC 4000 HPC 5000 WPC 7000 WPC 9000 WPC 15000...

Page 31: ...ORT HAS BEEN MADE TO PROVIDE PROD UCT INFORMATION AND ILLUSTRATE THE PRODUCTS IN THIS LITERATURE ACCURATELY HOWEVER SUCH INFORMATION AND ILLUSTRATIONS ARE FOR THE SOLE PURPOSE OF IDENTIFICATION AND DO...

Page 32: ...unauthorized person vi modifications or alterations to the Products vii use with parts or devices not supplied or approved by AmeriCool viii improper installation or service ix shipping damage to any...

Reviews: