www
.
W
elltec
.
pro
50
Question:
Why is the
„
FULL
”
LED flashing?
Answer:
Empty the machine's water tank. After installing the empty tank, the
„
FULL
”
LED
will stop flashing.
Q:
Why is the device working louder than usual?
A:
Possible cause is high filter contamination. It should be cleaned or vacuumed.
Q:
Why is only the fan running and the
„
POWER
”
LED blinking?
A:
The flashing
„
POWER
”
LED indicates that the unit's compressor is off. If the
„
DEH
”
LED is
lit at the same time, it means that the device has started the defrosting procedure. When
the compressor is off, it can also mean that the dehumidification process has been
completed or that it cannot be restarted too quickly.
Q:
Why did the airflow in the device decrease?
A
: Possible cause is filter contamination. It should be cleaned or replaced.
Q:
How long do device filters suffice?
A
: The carbon filter and pre-filter do not need to be changed. Just clean them regularly. The
carbon filter should be exposed to sunlight from time to time to regenerate carbon
molecules.