background image

11

During the radio-frequency treatment you do not necessarily notice 
a strong heat generation on your skin. This is because the radio-
frequency waves of the Body Lifter are especially matched to the 
body's skin. In this way, they warm the skin but do not cause any 
excessive heat sensation in the sensitive receptors, especially those 
in the upper skin layers. Nonetheless the effective breakdown of 
subcutaneous fat deep under the skin is stimulated and the collagen 
fibres in the connective tissue caused to become firmer. Also be aware 
that the sensation of heat depends very much on your skin´s specific 
characteristics, such as thickness and proportion of fat.

The BYAS Body Lifter operates with the BYAS-exclusive ATSEC

®

 

System (Automatic Temperature Safety Control). This allows a constant 
measuring of the skin temperature during the RF programmes through 
the quad treatment electrodes. If the warmth absorbed by the skin 
within a treatment reaches the programmed lower skin temperature limit 
of 42 ° C, the BYAS-exclusive PES

®

 System (Personal efficacy system) 

reminds the user with a pulsating acoustic signal during the treatment 
to move the Body Lifter to another part of the chosen body area. When 
the skin temperature reaches the programmed maximum temperature 
of 45 ° C, the pulsating acoustic signal becomes continuous, lasting 
for about 3 or 4s. Simultaneously, the Body Lifter´s output is stopped 
to allow the skin temperature to fall. As soon as the skin temperature 
starts declining, the continuous acoustic signal becomes pulsating 
again. When the measured warmth in the skin reaches 42 ° C again, 
the Body Lifter´s output is continued. If the skin temperature declines 
below 42 ° C, the pulsating acoustic signal stops automatically.

The Body Lifter´s High Frequency Electrical Muscle Stimulation 
Technology (HF-EMS

®

) strengthens and firms the muscles in a highly 

effective way. HF-EMS

®

 is even compatible with sensitive skin types, as 

the EMS´s pulse activation is specially tailored to the sensitive muscle 
structures.

After you have chosen an EMS programme, carry out the treatment as 
follows: Place the Body Lifter´s quad treatment electrodes on the area 
to be treated and simply start to carry out slow, stroking movements 
with the Body Lifter.

Do not treat any region of the body twice on the same 
day 

With three treatment days per week – always with one 
treatment-free day between each treatment day – you have the 
right rhythm for success in obtaining optimal results with the 
Body Lifter.

Always keep to the following treatment sequence to 
ensure optimum effects

1. 

Lay the Body Lifter´s quad treatment heads of the on the first  

   part of the area of the skin to be treated.

2. Move the Body Lifter twice in circular movements for 
   3 - 4 seconds over a plum-sized part of the treatment area without  
   applying any pressure!

3. Then, lay the quad treatment heads on the next plum sized part  
   of the skin area to be treated and repeat the whole process until  
   you have treated the whole area of the  
   skin to be treated completely.

RADIO-FREQUENCY APPLICATIONS

EMS APPLICATIONS

Summary of Contents for BYAS

Page 1: ...DISCOVER BYAS PROFESSIONAL HOME BEAUTY HI TECH USER MANUAL AND PRODUCTION INFORMATION...

Page 2: ...at the same time as effective as possible The BYAS PERFECTION SYSTEM combines the latest research worldwide in a holistic hybrid concept in which three unique modules interact in a highly effective wa...

Page 3: ...CONTENTS SHORT OVERVIEW 03 TREATMENT ADVICES 05 RADIOFREQUENCY PROGRAMMES 07 EMS PROGRAMMES 13 BYAS BODY FORMING GEL 19 WARNINGS AND CARE INSTRUCTIONS 21 CONTRAINDICATIONS 22 CONFIRMATION OF CONFORMI...

Page 4: ...our weekly fitness programme then it s time for you to do so WHAT IS THE BYAS BODY LIFTER The Body Lifter is a part of the BYAS Professional Home Beauty Hi Tech Device series Achieve fantastic body fo...

Page 5: ...t triglycerides HF EMS High Frequency Electrical Muscle Stimulation A high frequent pulse activation strengthens the body muscles in a highly effective way and offers simultaneously highest compatibil...

Page 6: ...ly to select approx 1 sec arms ARM waist WAI abdomen ABD buttocks BUT hip HIP legs LEG Choose treatment programme Press the button on the left side of the device B each time shortly approx 1 sec Defau...

Page 7: ...ny pressure onto the skin during a treatment Make sure there is always enough gel under the electrodes Interrupt Continue Press button A approx 2 sec Security System ATSEC PES Pulsating beep tones fro...

Page 8: ...status Display of the intensity level and the current operating status active standby 2 Battery symbol Display of the current charge state 3 Multi function button Select RF EMS programmes and program...

Page 9: ...output regulation when the maximum temperature is or is not exceeded Automatic temperature safety control ATSEC 7 PES Integrated acoustic guidance system that leads the user individually through the R...

Page 10: ...eatment heads have to contact the skin evenly Hold the Body Lifter in such a way that all four treatment heads contact the skin evenly This important because otherwise the depth effect of the Body Lif...

Page 11: ...e to fall As soon as the skin temperature starts declining the continuous acoustic signal becomes pulsating again When the measured warmth in the skin reaches 42 C again the Body Lifter s output is co...

Page 12: ...reas of the body move step by step Carry out the treatments successively each with palm sized parts you have previously applied gel on When carrying out a treatment always ensure that the four treatme...

Page 13: ...t side of the device shortly 1 s per programme SLIM Slimming is the first RF programme 4 Thirdly select the intensity level for the programme you have chosen Press the left multi function button again...

Page 14: ...of the Body Lifter touch the skin evenly to achieve optimal results with the Body Lifter Do not apply any pressure onto the skin during the treatment The Body Lifter s own weight offers enough pressu...

Page 15: ...ft side of the device shortly 1 s per programme SHAPE Shaping is the third RF programme 4 Thirdly select the intensity level for the programme you have chosen Press the left multi function button agai...

Page 16: ...t to treat larger areas of the body move step by step Carry out the treatments successively each with palm sized parts you have previously applied gel on When carrying out a treatment always ensure th...

Page 17: ...t side of the device shortly 1 s per programme STRET Stretching is the third RF programme 4 Thirdly select the intensity level for the programme you have chosen Press the left multi function button ag...

Page 18: ...ng that is less intense Apply the BYAS Body Firming Gel with the active body shaping LIPOrelease special ingredient complex generously to the area to be treated If you want to treat larger areas of th...

Page 19: ...device shortly 1 s per programme SMTH Smoothing is the first EMS programme after the three RF programmes 4 Thirdly select the intensity level for the programme you have chosen Press the left multi fun...

Page 20: ...uscles Apply the BYAS Body Firming Gel with the active body shaping LIPOrelease special ingredient complex generously to the area to be treated If you want to treat larger areas of the body move step...

Page 21: ...device shortly 1 s per programme FIRM Firming is the second EMS programme after the three RF programmes 4 Thirdly select the intensity level for the programme you have chosen Press the left multi func...

Page 22: ...the muscles Apply the BYAS Body Firming Gel with the active body shaping LIPOrelease special ingredient complex generously to the area to be treated If you want to treat larger areas of the body move...

Page 23: ...device shortly 1 s per programme LIFT Lifting is the third EMS programme after the three RF programmes 4 Thirdly select the intensity level for the programme you have chosen Press the left multi func...

Page 24: ...effect on the breakdown of fats Lipolysis Clinical studies in the field show a detectable anti cellulite effect after just two weeks DOUBLE EFFECT LIPORELEASE SPECIAL COMPLEX Consists of a highly inno...

Page 25: ...There they act as a catalyst to enhance the effects of the Body Lifter with their special fat formation restriction and fat breakdown stimulation properties APPLICATION INSTRUCTIONS All skin types Fo...

Page 26: ...is always enough gel under the treatment heads to avoid possible skin irritations Increase the amount of gel used if necessary particularly when you have a strong sensation of warmth on the skin duri...

Page 27: ...r rashes By persons who have had surgery laser treatment or deep action chemical peeling in the treatment area within the past 3 months or the consequences of such interventions have not yet completel...

Page 28: ...NFORMITY We confirm that the BYAS Body Lifter complies with the guidelines of the EU regulation 2011 65 EU Restriction of hazardous substances in electrical and electronic equipment 2014 30 EU electro...

Reviews: