background image

M504  p/n 2M-303903  Owners Manual WV

-4H V

entless Hotplate Cooktop 

5

FEATURES & OPERATING CONTROLS (continued)

ITEM

DESCRIPTION

COMMENT

VENTILATOR SECTION CONTROLS

V1

POWER SWITCH

Energizes blower motor.  If, after 10 seconds, proper     

conditions are met, cooktop is energized.

V2

POWER 

ON

 INDICATOR

GREEN.  Glows when POWER switch is 

ON.

V3

CHECK FILTERS 

ALARM 

INDICATOR

AMBER.  Glows if one or more filters are out of position.  Check all 

filters and baffles for proper installation.

V4*

REPLACE PREFILTER 

ALARM 

INDICATOR

AMBER.  Glows when PREFILTER is approaching the end of its 

service life and must soon be replaced.

V5*

REPLACE FILTER PACK ALARM 

INDICATOR

AMBER.  Glows when FILTER PACK is approaching the end of its 

service life and must soon be replaced.

V6*

SERVICE REQUIRED ALARM 

INDICATOR

RED.  Glows when PREFILTER and/or FILTER PACK has reached 

the end of its service life and is too loaded to allow   sufficient air 

flow.  Filter MUST be replaced.  Appliance is 

SHUT DOWN 

until 

expended filters are replaced.

COOKTOP SECTION CONTROLS

H1

LEFT FRONT HOTPLATE CONTROL

Infinite switch control of temperature of one hotplate section.

H2

LEFT REAR HOTPLATE CONTROL

Infinite switch control of temperature of one hotplate section.

H3

RIGHT REAR HOTPLATE CONTROL

Infinite switch control of temperature of one hotplate section.

H4

RIGHT FRONT HOTPLATE CONTROL

Infinite switch control of temperature of one hotplate section.

H5

POWER ON INDICATOR

AMBER.  Glows when temperature control is turned 

ON.

OPTIONAL WARMER SECTION CONTROLS

  

W.01

TEMPERATURE CONTROL 

Infinite switch control of temperature of one warmer drawer.

  W.02

POWER ON INDICATOR

AMBER.  Glows when associated temperature control is turned 

ON.

  W.03

THERMOMETER (optional)

Reads temperature inside drawer cavity.  Must be ordered at time of initial 

build. 

  W.04

HUMIDITY CONTROL

Slide control of shutters to control air circulation within the warmer drawer.

  W.05

DRAWER CATCH

Holds drawer closed.

  W.06

DRAWER STOP

Prevents drawer from opening too far.  Spring loaded to permit easy removal 

of drawer.

  W.07

DRAWER ROLLERS

Support drawer and allow it to open and close smoothly.

  W.08

POWER SWITCH (RWT)

Energizes unit (RWT-style only)

  W.09

CONTROLLER

Controls cavity temperature.  Readout displays setpoint and actual 

temperature information.  UP ARROW / DOWN ARROW keys allow 

modification of setpoint temperature. (RWT-style units only)

Summary of Contents for WV-4H Series

Page 1: ...manual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals...

Page 2: ...type Normal Business Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www Wells Mfg com WARRANTY EXCLUSIONS THE FOLLOWING WILL NOT BE CO...

Page 3: ...ong economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance T...

Page 4: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 2 FEATURES OPERATING CONTROLS Fig 1 Ventilator Section Operating Features Controls...

Page 5: ...s larger particles of grease from reaching the FILTER PACK for reduced maintenance costs 19 HEPA CHARCOAL FILTER PACK Stops most grease and smoke particles Also assists in some cooking odor removal 22...

Page 6: ...al WV 4H Ventless Hotplate Cooktop 4 FEATURES OPERATING CONTROLS continued Fig 2 Ventilator Section Controls Indicator Lights Fig 4 Cooktop Warmer Drawer Operating Features Controls Fig 3 Cooktop Sect...

Page 7: ...of temperature of one hotplate section H2 LEFT REAR HOTPLATE CONTROL Infinite switch control of temperature of one hotplate section H3 RIGHT REAR HOTPLATE CONTROL Infinite switch control of temperatu...

Page 8: ...installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and schedules to ensure the safety of the food product Disco...

Page 9: ...ou may experience an extended down time with consequent associated loss of business The manufacturer assumes no liability for loss of business due to a system shutdown caused by a dirty pre filter and...

Page 10: ...led as soon as possible 1 ea FIRE SUPPRESSION AGENT ANSULEX Low pH 1 5 GAL See Material Safety Data Sheet page 22 1 ea FIRE SUPPRESSION MEDIA TANK 1 ea FIRE SUPPRESSION TANK CHARGING CARTRIDGE 1 ea GR...

Page 11: ...the specifications listed on page 1 Incoming wiring must comply with National Electrical Code specifications All cooktop universal hood appliances ship from the factory wired 3 and include a 3 cordse...

Page 12: ...ized and a buzzer will sound continuously The fire suppression media will form an emulsion designed to both smother and cool the fire Call your Authorized Ansul Distributor immediately for service NOT...

Page 13: ...st the bottom of the assembly pull the FILTER HANDLE toward you so as to engage the FILTER HOOK over the lip of the top filter rail Then lower and seat the assembly into the top indentation of the low...

Page 14: ...oking surface causing splattering of hot liquids Serious injury can result from contact with hot splatter GREASE TROUGH AND GREASE CUP INSTALLATION 1 Install the GREASE TROUGH into the brackets below...

Page 15: ...Note The REPLACE PRE FILTER and REPLACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life The appliance will continue to operate for a period of time after...

Page 16: ...ing element is controlled by an infinite switch temperature control OFF removes power from the element LOW thru 8 are temperature settings Higher numbers indicate higher temperatures There is a contin...

Page 17: ...o support the food off of the steam vents where water droplets may form e Check the water level in the pan periodically and add water when necessary f Set the front air vent between fully closed and h...

Page 18: ...N arrow keys for 10 seconds Release keys when display reads F C Within 3 seconds press UP arrow or DOWN arrow key until desired indicator F or C glows The new value will lock into memory 3 seconds aft...

Page 19: ...TOOLS Warm water and a mild detergent Soft clean cloth or sponge Plastic scouring pad plastic scraper Disconnect appliance from electric power Allow to cool before cleaning Spiral Hotplate Elements Ra...

Page 20: ...and warm water Allow to air dry 4 Reinsert the pre filter into the filter frame Reinstall the pre filter grease baffle grease trough and grease cup Procedure is complete CAUTION ELECTRIC SHOCK HAZARD...

Page 21: ...or metal implements to clean cabinet surfaces VENTILATOR MONTHLY CLEANING PREPARATION Disconnect appliance from electric power Allow to cool before cleaning FREQUENCY Monthly TOOLS Warm water and a mi...

Page 22: ...ty 4 Clean the outside of the unit by wiping with a clean cloth or sponge warm water and mild detergent Dry with a clean cloth then wipe with a polish formulated for stainless steel 5 It is important...

Page 23: ...ISTRIBUTOR ONLY a Inspect and test total operation including FIRE DAMPER and all SAFETY INTERLOCKS b All FIRE SUPPRESSION SYSTEM actuation components including MANUAL PULL STATION and any REMOTE MANUA...

Page 24: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 22...

Page 25: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 23...

Page 26: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 24...

Page 27: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 25...

Page 28: ...REPLACE PREFILTER light on Pre filter clogged but still operational Replace pre filter at first opportunity REPLACE FILTER PACK light on Filter pack clogged but still operational Replace filter pack a...

Page 29: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 27 PARTS BREAKDOWN for ANSUL COMPONENTS...

Page 30: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 28 EXPLODED VIEW PARTS LIST HOOD CABINET COMPONENTS...

Page 31: ...GHT BULB 100W 230V FROSTED 4 2Q 305099 GLASS GLOBE VCS HOOD 5 M3 304405 TRAY GREASE DRIP HOOD 6 5E 20804 CASTER ASSY 2FIX 2SWVL 7 5M 22649 KIT LEG REAR OPT WVF WVG 8 M3 302646 DOOR ASSY RIGHT 9 2R 465...

Page 32: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 30 EXPLODED VIEW PARTS LIST HOOD ELECTRICAL VACUUM COMPONENTS...

Page 33: ...CH ROCKER 240V 20A 9 2J 35697 PILOT LT GREEN 250V 1 3W 10 2J 30516 LIGHT SIGNAL AMBER 11 2J 31157 LIGHT SIGNAL RED 12 2J 44834 BUZZER 220V ROHS 13 2E 300407 SWITCH MANUAL ADVANCE 14 2E 34005 JUMPER FL...

Page 34: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 32 EXPLODED VIEW PARTS LIST COOKTOP COMPONENTS...

Page 35: ...ATE UPGRADE FUSED WIRE 2 DD 501451 BRKT SOLID ELEM HOLD DOWN 3 2C 31053 NUT 8 32 KEPS MS NICKEL 4 2C 33977 SCREW 8 32X3 8 PHBNDHD 5 WS 50293 ELMNT ASSY KIT 240V 2600W 6 2R 30584 KNOB HOTPLATE REAR 7 2...

Page 36: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 34 EXPLODED VIEW PARTS LIST DRAWER WARMER COMPONENTS...

Page 37: ...1 DRAWER STRIKER AND CATCH 10 2P 30483 BRNG RLLR TRK R116 11 C8 32112 HANDLE RW DRAWER SRW 12 WS 51796 KNOB SQUARE ROLL WARMER 13 2T 44475 THERMOMETER RW 2IN DIAL 14 2N 30482UL ELEM 240V 450W 208 240V...

Page 38: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 36 WIRING DIAGRAM HOOD SECTION...

Page 39: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 37 WIRING DIAGRAM HOTPLATE COOKTOP SECTION...

Page 40: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 38 WIRING DIAGRAM DRAWER WARMER SECTION RW STYLE DRAWER WARMER SECTION RWT STYLE...

Page 41: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 39 NOTES...

Page 42: ...M504 p n 2M 303903 Owners Manual WV 4H Ventless Hotplate Cooktop 40 NOTES...

Page 43: ...se have this information available if calling for service RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________________ TECHNICIAN ___________ SERVICE COMP...

Page 44: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 800 264 7827 www wells mfg com...

Reviews: