UNPACKING & INSPECTION 

 

Carefully remove the appliance from the carton.  Remove all  
protective plastic film, packing materials and accessories from the 
Appliance before connecting electrical power or otherwise performing 
any installation procedure. 

 
Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 

 
Read and understand all labels and diagrams attached to the 
appliance. 

 
Carefully account for all components and accessories before 
discarding packing materials.  Store all accessories in a convenient 
place for later use.

 

 
INSTALLATION NOTES 

 

     1. 

Installation and start up of built-in warmers MUST be performed 

 

 

by an authorized installation company. 

     2. 

It is the RESPONSIBILITY OF THE INSTALLER to verify that 

 

 

this warmer installation is in  compliance with the specifications 

 

 

listed in this manual and on the specification sheet provided.  

     3. 

It is the RESPONSIBILITY OF THE INSTALLER to check with 

 

 

the AUTHORITY HAVING JURISDICTION, in order  to verify 

 

 

that this warmer installation is in compliance with local code  

   requirements. 
 

4.  Water supply and drain installation must meet all applicable   

 

 

local, state and federal plumbing codes and ordinances. 

 5. 

Refer 

to 

Installation Instructions

 included with the warmer for                

 

 

Underwriters Laboratories conditions of acceptability, electrical          

 

 

requirements and other installation concerns. 

 
BUILT-IN WARMERS 

 
     1. 

This is a GENERAL GUIDE.  For specific  

 

 

cutout dimensions and other installation   

 

 

details, refer to the 

Installation Instructions

  

 

 

supplied with the warmer. 

 

 

2.  Cutout dimensions for warmer units and   

 

 

control panels are listed on the 

Installation  

   Instructions 

provided with the warmer. 

 

3.  Verify style of control panel (i.e. square,  

 

 

oval, etc.) before making cutout. 

 
 

NOTE

:  Cutout dimensions are different for  

 

square and oval control panels, and  for  wood 

 

and metal counters.  Verify the dimensions are 

 

correct for the installation before making the 

 cutout.

 

 INSTALLATION 

SQUARE 

OVAL 

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 
 

 

WARNING: 

RISK OF  INJURY 

 

Installation procedures must 
be performed by a qualified 
technician with full knowledge 
of all applicable electrical and 
plumbing codes.  Failure can 
result in personal injury and 
property damage. 

 

 

CAUTION 

FIRE HAZARD 

 

Avoid storing flammable or 
combustible materials in, on 
or near the appliance. 
 
 

IMPORTANT:  

For warmers 

installed in plastic counter 
tops, the counter material 
must be protected from the 
heat of the warmer in order to 
prevent discoloration and/or 
deterioration.  Wellsloks are 
not suitable for this purpose.  
The installer should contact 
the  manufacturer or distributor 
of the countertop material for 
specific instructions.  

 

 

 M
012D.01 

 2M

-308034 

  Owne

rs M

anual fo

r Built-In

 Rou

nd-

W
e

ll Inf.Sw

W
a

rmers 

Summary of Contents for SS10 Series

Page 1: ...TOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installation operation or maintenance of this equipment OWNERS MANUAL DROP IN ROUN...

Page 2: ...CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier imm...

Page 3: ...re that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance i...

Page 4: ...y position other than OFF 4 The TEMPERATURE CONTROL KNOB will rotate without stopping with PREHEAT and OFF having obvious detents The OFF position is a positive OFF i e the switch is positively held i...

Page 5: ...direct water jet or steam jet at this appliance or at any control panel or wiring Do not splash or pour water on in or over any controls control panel or wiring Exposed surfaces of this appliance can...

Page 6: ...nd other installation concerns BUILT IN WARMERS 1 This is a GENERAL GUIDE For specific cutout dimensions and other installation details refer to the Installation Instructions supplied with the warmer...

Page 7: ...le specifications of local codes and of the National Electrical Code PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel...

Page 8: ...e available as accessories in 2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Infinite Switch Controlled Warmers Turn temperature co...

Page 9: ...l Warmer pans insets and other vessels are subject to a harsher environment Wells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stain...

Page 10: ...eal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fire and or electric shock hazard 5...

Page 11: ...or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overn...

Page 12: ...uthorized Wells Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must match vol...

Page 13: ...8 WELLS WELLS H I H I PILOT LIGHT RETAINER CLIP 2C 43271 POP RIVET 2C 34284 CONTROL KNOB ASSEMBLY 2R 44373 RED LIGHT SIGNAL WS 50385 CONTROL PANEL 2V WL0040 INFINITE SWITCH 2E 30570 120V 2E 30562 240V...

Page 14: ...ld 7 qt inset 5D 20175 ADAPTER TOP convert SS 206 to hold two 7 qt insets 5D 20176 2 QT ROUND INSET w lid 5D 20773 4 QT ROUND INSET w lid 5D 20774 7 QT ROUND INSET w lid 5D 20587 11 QT ROUND INSET w l...

Page 15: ...CCESSORIES 6 oz SOUP LADLE DD 21764 DRAIN VALVE EXTENSION KIT extension from drain to counter front with remote handle for use with D models only excluding DM models 5P 20385 PARTS SERVICE 13 IMPORTAN...

Page 16: ...WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...

Reviews: