background image

11

1  p/n 

2M-303340

    OpManual Built-In Electric Griddles

3

This appliance is intended for use in commercial establishments 

only.
This appliance is intended to prepare food for human consumption.  

No other use is recommended or authorized by the manufacturer or its 

agents.
Operators of this appliance must be familiar with the appliance use, 

limitations and associated restrictions.  Operating instructions must be 

read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation.  Read and 

follow all included cleaning instructions and schedules to ensure the 

safety of the food product.
Disconnect this appliance from electrical power before performing any 

maintenance or servicing.
DO NOT submerge this appliance in water.  This appliance is not jet 

stream approved.  Do not direct water jet or steam jet at this appliance, 

or at any control panel or wiring.  Do not splash or pour water on, in or 

over any controls,  control panel or wiring. 
Exposed surfaces of this appliance can be hot to the touch and may 

cause burns.
The technical content of this manual, including any wiring diagrams,

schematics, parts breakdown illustrations and/or adjustment

procedures, is intended for use by qualified technical personnel.

Any procedure which requires the use of tools must be performed by a 

qualified technician.

This manual is considered to be a permanent part of the appliance.  

This manual and all supplied instructions, diagrams, schematics, parts 

breakdown illustrations, notices and labels must remain with the

appliance if it is sold or moved to another location.
This appliance is made in the USA.  Unless otherwise noted, this

appliance has American sizes on all hardware.

CAUTION:

RISK OF

DAMAGE

DO NOT connect or energize 

this appliance until all 

installation instructions are 

read and followed.  Damage 

to the appliance will result if 

these instructions are not

followed.

CAUTION:

HOT SURFACE

Exposed surfaces can be hot 

to the touch and may cause 

burns.

PRECAUTIONS AND GENERAL INFORMATION

DANGER:  

BURN HAZARD

Contact with cooking surface cause severe burns. Always wear protective clothing 

and avoid contact with griddle surface.

WARNING:  

ELECTRIC SHOCK HAZARD

All servicing requiring access to non-insulated components must be performed by 

qualified service personnel.  DO NOT open any access panel that requires the use   

of tools.  Failure to heed this warning may result in severe electric shock.

Summary of Contents for G-136

Page 1: ...RAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS...

Page 2: ...the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merch...

Page 3: ...ppliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS SPECIFICATIONS STANDARD GRIDDLES INTRODUCTION 1 MODEL VOLTS WATTS AMPS 3 AMPS L1...

Page 4: ...ividually controllable Dial position is an indication of the temperature setting The actual temperature at the griddle surface will vary depending upon the initial type and temperature of the product...

Page 5: ...ing any wiring diagrams schematics parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel Any procedure which requires the use of tools must be...

Page 6: ...ith the griddle c Refer to the Installation Instructions for Underwriters Laboratories Conditions of Acceptability Mounting the griddle a Verify that provided sealants are applied to the under side of...

Page 7: ...to the wrong voltage or phase is NOT covered by warranty ELECTRICAL INSTALLATION Refer to the nameplate Verify the electrical service power Voltage and phase must match the nameplate specifications C...

Page 8: ...USING THE GRIDDLE Check the chart on page 7 for recommended cooking temperatures Turn temperature control knob to the desired temperature The heating indicator light will glow while the griddle is hea...

Page 9: ...tries to compensate for heat lost to the low section Teppan griddle JG 246UL heats in the center two quadrants only The outer two quadrants are used for holding prepared food at temperature RECOMMEND...

Page 10: ...ove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease drawer After scraping all cooking waste from grease trough into the grease drawer take the gr...

Page 11: ...e drawer After scraping all cooking waste from grease trough into the grease drawer take the grease drawer to kitchen cleaning area and properly dispose of all waste a Clean drawer with hot water and...

Page 12: ...set to desired temperature Set to desired temperature Damaged internal component Contact Wells Authorized Service Agency for repairs Griddle drips grease Grease drawer full or not installed Empty grea...

Page 13: ...G136 Cabinet Electrical BUILT IN ELECTRIC GRIDDLE MODEL G136 CABINET ELECTRICAL 208 240V and 480V KNOB 2R 50259 IL1909 Rev B PL111 MODEL G136 GG136 PG136 CABINET ELECTRICAL 208 240V 380 415V and 480V...

Page 14: ...N ELECTRIC GRIDDLE MODEL G136 G136 HEATING ELEMENTS 208 240V and 480V 12 EXPLODED VIEW G136 Heating Elements GRIDDLE REF shown inverted FRONT IL1908 Rev B PL111 28 29 30 31 32 33 34 35 36 37 38 MODEL...

Page 15: ...1 16 X 2 X 15FT 0 4 G136 11 2C 31053 NUT 8 32 KEPS MS NICKEL 8 G136 G136 480V 9 G136 400 12 2C 31734 SCREW 8 32X2 1 4 SL RDHD 2 G136 13 G7 31989 SHROUD DRWR G13 136 19 19 1 G136 14 2C 33935 SCREW 6ABX...

Page 16: ...2 G136 400 GG136 400 34 2E 32054 JUMPER ELEMENT MEDIUM 4 G136 G136 480V 35 2N 30496UL ELEMENT 240V 2250W 4 G136 2N 45922UL ELEM 220V 4500W EU 2 G136 400 GG136 400 2N 48904UL ELEM HEATING 480V 2250W 4...

Page 17: ...In Electric Griddles PARTS LIST G136 BUILT IN ELECTRIC GRIDDLE MODEL G196 HEATING ELEMENTS 208V 240V 380 415V and 480V IL1910 PL111 MODEL G196 HEATING ELEMENTS 208 240V and 480V GRIDDLE SHOWN INVERTE...

Page 18: ...es 16 EXPLODED VIEW G196 BUILT IN ELECTRIC GRIDDLE MODEL G196 CABINET ELECTRICAL 208V 240V 380 415V and 480V ELECTRIC GRIDDLE G 196 CABINET COMPONENTS W ELLS IL1911 Rev B PL111 12 13 14 15 16 17 36 35...

Page 19: ...5 16X132 G196 1 18 2E 37465 TERM BLOCK 3POLE 85AMP 1 208V 240V 480V 2E 40310 TERM BLOCK 4POLE 75AMP 380 415V 19 2C 41974 NUT 8 32 HEX 7 8 LONG ALU 2 20 2K 31040 BUSHING HEYCO 7 8 OD 2 21 1P 36178 TAP...

Page 20: ...UL 800W 480V 2N 31495UL 4 ea NUT 10 32 HEX 2C 35313 NUT 1 4 20 HEX Ni 2C 31253 36 ea CLAMP ELEM CENTER DD 32037 10 ea CLAMP ELEM END G7 32038 8 ea CLAMP PERIMETER ELEMENT RIGHT G7 32026 CLAMP PERIMETE...

Page 21: ...2K 31040 NUT HEX ALUMINUM 8 32 x 7 8 2C 41974 HANDLE 2R 38668 TRAY FRONT G7 Z12047 GREASE DRAWER COMPLETE ASSY WS 50279 GRIDDLE PLATE ASSEMBLY SPLASHGUARD LEFT G7 35783 SPLASHGUARD RIGHT G7 35782 SMOO...

Page 22: ...27 CLAMP ELEM PERIM G7 32025 8 ea CLAMP THERMO BULB GRIDDLE G7 32028 12 ea ELEM PERIM 240V 1000W 2N 30507UL 480V 1000W 2N 31498UL ELEMENT 8ea 208V 2500W 2N 30513UL 240V 2500W 2N 30520UL 480V 2500W 2N...

Page 23: ...ELLS SHROUD GREASE DRAWER WS 51989 HANDLE 2R 38668 TRAY FRONT G7 Z12047 GREASE DRAWER COMPLETE ASSY WS 50279 LIGHT SIGNAL AMBER 208 240V 2J 30516 480V M3 WL0113 4 reqd KNOB 2R 30259 4 reqd SHIELD THE...

Page 24: ...2038 16 ea CLAMP PERIMETER ELEMENT RIGHT 2 ea G7 32026 CLAMP PERIMETER ELEMENT LEFT 2 ea G7 32027 CLAMP THERMO G7 32028 24 ea TUBE THERMO 2A 31971 8 ea CLIP INSULATION G7 33474 24 ea pk12 COVER GREASE...

Page 25: ...2 reqd BUSHING HEYCO 7 8 2K 31040 4 reqd NUT HEX ALUMINUM 8 32 x 7 8 2C 41974 4 reqd THERMO CONTROL 2T 30257 8 reqd LIGHT SIGNAL AMBER 208 240V 2J 30516 480V M3 WL0113 8 reqd KNOB 2R 30259 8 reqd COV...

Page 26: ...TOP ELECTRIC TEPPAN YAKI GRIDDLE MODEL JG246UL CABINET HEATING ELEMENTS 208 240V 480V GRIDDLE ref shown inverted 2N 41738UL 208 240V 2 ea 2N 304817UL 480V 2 ea I7 41830 2 ea G7 33474 6 ea G7 46178 2C...

Page 27: ...6X 2 ea 2I Z12311 2 ea 2C 35736 WS 50131 2C 41974 2 ea 1P 36178 1 16 x2 x12 1O 32040 3 DD 45655 2P 2E 300355 1P 2C 31053 2T 46162 2E 30330 2C 33935 22 ea 2E 33192 2R 300356 1 5 0 200 25 0 30 0 350 4 0...

Page 28: ...208 volt and 240 volt griddles are field convertible to single phase CONTROL KNOB CONFIGURATION For all models control knob p n 50259 is marked in degrees Fahrenheit from 200 F to 450 F When the ther...

Page 29: ...Griddles are field convertible to single phase CONTROL KNOB CONFIGURATION For Teppan Griddles control knob p n 500536 is marked in degrees Fahrenheit from 150 F to 550 F When the thermostat is OFF th...

Page 30: ...111 p n 2M 303340 OpManual Built In Electric Griddles 28 WIRING DIAGRAM...

Page 31: ...29 WIRING DIAGRAM G196 111 p n 2M 303340 OpManual Built In Electric Griddles...

Page 32: ...340 OpManual Built In Electric Griddles 30 WIRING DIAGRAM G236 L1 L2 L3 208 48 3 51 3 35 0 76 9 240 41 7 44 4 30 4 66 6 480 20 9 22 2 15 5 33 3 NORMAL AMPS PER LINE AMPS 3PH 16 VOLTS KW AMPS 1PH p n 2...

Page 33: ...31 WIRING DIAGRAM G246 111 p n 2M 303340 OpManual Built In Electric Griddles...

Page 34: ...111 p n 2M 303340 OpManual Built In Electric Griddles 32 WIRING DIAGRAM G606...

Page 35: ...33 WIRING DIAGRAM JG246UL 111 p n 2M 303340 OpManual Built In Electric Griddles...

Page 36: ...111 p n 2M 303340 OpManual Built In Electric Griddles 34 NOTES...

Page 37: ...35 NOTES 111 p n 2M 303340 OpManual Built In Electric Griddles...

Page 38: ...111 p n 2M 303340 OpManual Built In Electric Griddles 36 NOTES...

Page 39: ...________________________________________________ ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER _____ _____ _________ EQUIPMENT MODEL NO _____________ EQUIP SERIAL NO...

Page 40: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...

Reviews: