![Wells G-136 Owner'S Manual Download Page 29](http://html1.mh-extra.com/html/wells/g-136/g-136_owners-manual_955734029.webp)
11
1 p/n
2M-303340
OpManual Built-In Electric Griddles
27
WIRING DIAGRAM
JG246UL TEPPAN GRIDDLE
FIELD CONVERSION FROM 3-PHASE TO SINGLE-PHASE
Griddles are shipped from the factory wired for 3-phase power,
Teppan Griddles are field convertible to single-phase.
CONTROL KNOB CONFIGURATION
For Teppan Griddles, control knob p/n 500536 is marked in degrees Fahrenheit from 150ºF to 550ºF.
When the thermostat is
OFF
, the flat of the control shaft is positioned on the top.
SPECIFICATIONS - JG-246UL
MODEL
VOLTS
WATTS
AMPS 3ø AMPS 3ø AMPS 3ø AMPS 3ø
AMPS
L1
L2
L3
N
1ø
JG-246UL
208V
6,000
14.4
25
14.4
28.9
240V
8,000
16.7
28.9
16.7
33.3
Summary of Contents for G-136