background image

EQUIPMENT CLOSING:

 

Procedures:

 

1.      Turn thermostat knob count erclockwise to "OFF" position on label and unplug cord. 
2.      Remove inset from cooker. 
3.      Dispose of any soup remaining in inset, then wash inset and cover with hot water and detergent. 
4.      Allow cooker to cool and then remove the water remaining in well. 

 NOTE: DO NOT IMMERSE COOKING UNIT IN WATER. DO NOT SPLASH OR SPRAY WATER ON UNIT.

 

5.      Clean cooker unit with damp cloth and then dry. 

 NOTE: DO NOT USE ABRASIVE CLEANERS THAT MAY DAMAGE THE EXTERIOR FINISH OF THE 

SOUP COOKER. 

6.      Use a plastic scouring pad to remove any hardened food particles. 

IMPORTANT: DO NOT USE STEEL 

WOOL FOR CLEANING.

 

7.      Rinse Cooker thoroughly with a vinegar and water solution to neutralize all detergent/cleaner 

 residue. 

 IMPORTANT: LIMIT USE OF STRONG/CAUSTIC CLEANERS ON WARMERS. DO NOT ALLOW AM-

MONIA TO STAND IN COOKER. MAKE SURE TO RINSE THOROUGHLY TO REMOVE 
ALL RESIDUE. FAILING TO DO SO MAY CAUSEDAMAGE/CORROSION TO UNIT.

 

 WARNING:     DO NOT USE ANY HIGHLY CAUSTIC CLEANERS ON COOKERS. USE OF THESE 

CLEANERS MAY CAUSE DAMAGE/CORROSION TO UNIT. 

8.      If water used to fill cooker has a high mineral content, cooker may develop lime deposits. Use a de-liming 

agent to remove lime deposits. It is important to use a de-liming agent often so deposits do not build up. 

Recommendation:

   If water has a high mineral content, a cartridge - type filtration device can be used to 

minimize lime build-up. 

Testing Procedure:

 

To check for proper operation and thermostat calibration, follow this procedure: 

1.     Fill Cooker well with a maximum of 32 Oz. (1.0 liters) of hot tap water. 
2.     Plug unit into electrical outlet (for 120V models 120 VAC, 15 AMP, and for 240V models 240 VAC). 
3.     Place inset into Cooker and fill inset with 40 oz. (1 

2.

 liters) of hot tap water and cover inset. 

4.     Turn thermostat knob to "SERVE" position on label. 
5.     Allow unit to heat until the small RED light shuts off. Allow unit to heat for 20 minutes to permit water 

temperature in cooker well to stabilize.  

WARNING:

    Handle inset with care, the water in inset is hot. 

6.     Insert thermometer into heated water in cooker well. Temperature should be 165° to 185°F (76° to85°C). 
7.     Replace inset and cover into cooker well. 
8.     Turn thermostat knob to "COOK" position on label. 
9.     Allow unit to heat for 20 minutes, to permit water temperature in cooker well to stabilize. 

10.    Carefully remove inset well cover from cooker well and set aside.  

WARNING:

   Handle inset with care, the water in inset is hot. 

11.    Insert thermometer into heated water in cooker well. The temperature should be 200°F+ (93°C) 

page 6 

Summary of Contents for 6423

Page 1: ...SOUP COOKER WARMER 120V 240V MODEL 6423 INSTRUCTIONS Installation Operation Maintenance WELLS MANUFACTURING COMPANY P O BOX 280 VERDI NEVADA 89439 702 345 0444 FAX 702 345 0569 ITEM NO 47566 3 98 ...

Page 2: ...Model 6423 is designed to cook soup frozen or canned and hold finished product at the correct temperature for serving Soup Cooker to be used for wet operation only SAFETY Knowledge of proper installation operation and maintenance procedures is essential to insure safe operation of any equipment The instructions in this chapter are meant as guidelines major considerations to be kept always in mind ...

Page 3: ...32 Oz 1 0 liters of hot tap water Filling the well with hot water will decrease the time required to bring the cooker up to full temperature 2 Plug power cord into appropriate electrical receptacle for 120V models 120 VAC 15 AMP and for 240V models 240 VAC 3 Turn thermostat knob clockwise to COOK position on label Allow at least 15 minutes for water bath to preheat Cover with lid to retain the hot...

Page 4: ...REPLACEMENT PARTS IDENTIFICATION FOR MODEL NO 6423 SOUP COOKER ...

Page 5: ... 4 20 Pack of 100 9 65644 65644 Control Knob 10 67493 67493 Label 11 80017 55540 Cord and Cap Assembly 12 68689 68689 Cord Grip Liquid Tight with metal locknut 13 67494 67667 Pilot Light 14 67499 67499 High Limit Thermostat 15 67498 67669 Heater Band w Screw Nut 16 67496 67496 Control Thermostat 17 67490 67490 Thermostat Bracket 18 66145 66145 Screw 6 32 x 3 16 Pack of 10 NOT SHOWN 67495 Wire Set ...

Page 6: ...iming agent to remove lime deposits It is important to use a de liming agent often so deposits do not build up Recommendation If water has a high mineral content a cartridge type filtration device can be used to minimize lime build up Testing Procedure To check for proper operation and thermostat calibration follow this procedure 1 Fill Cooker well with a maximum of 32 Oz 1 0 liters of hot tap wat...

Page 7: ...WIRING DIAGRAM FOR 6423 SOUP COOKER ...

Page 8: ...z Ladle 21861 Model 38 2 Qt Graduated Measure 21862 Model MG14 10 1 2 Inset with Handles 21863 Model SC14 Cover Assembly 21864 Model 1012 Cup Caddy Straight Bin 21865 Model 1022 Cup Caddy Sloped Bin ELECTRICAL INFORMATION Voltage 120V 60 Hz single phase Power 1 KW 8 3 amps Soup Cooker is provided with a 6 foot cord with a 5 15P straight plug PRODUCT FINISH All stainless steel construction PRODUCT ...

Page 9: ...lls Manufacturing Company 2 Erik Circle P O Box 280 Verdi NV 89439 702 345 0444 FAX 702 345 0569 TOLL FREE FAX 800 356 5142 for orders only 1994 Wells Manufacturing Company Printed in U S A Item No 48944 ...