background image

 

FOR USER

 

3. TECHNICAL SPECIFICATION   

 

Model 

GHD-150- 

0324 

GHD-150- 

0325 

GHD-150- 

0326 

GHD-150- 

0327 

GHD-150- 

0328 

GHD-150- 

0329 

GHD-150- 

0330 

GHD-150- 

0331 

GHD-150- 

0332 

GHD-150- 

0333 

Advised pool volume 

(m

3

15~30 

20~40 

25~45 

30~55 

35~65 

40~75 

50~95 

65~120 

65~120 

90~160 

Working air temp ( )

 

-7~43

 

Performance Condition: Air 26°C, Water 26°C, Humidity 80% 

Heating capacity (kW)                                       

6.5 

8.4   

10.3   

12.8   

15.0   

17.3   

20.4   

27.3   

27.0   

35.6   

C.O.P 

14.0~5.7 

14.1~7.0 

14.5~6.9 

15.0~7.4 

15.5~6.7 

14.8~5.9 

14.5~5.7 

14.6~6.2 

14.5~6.2 

14.6~5.5 

C.O.P at 50% speed     

10.0   

10.3   

10.4   

11.0   

10.9   

10.5   

10.2   

10.8   

10.8   

10.3   

Performance Condition: Air 15°C, Water 26°C, Humidity 70% 

Heating capacity (kW)                                     

4.8 

6.1 

7.1   

8.3   

10.5   

11.4   

14.0   

18.0   

18.0   

24.0   

C.O.P     

7.1~4.3 

7.0~4.8 

7.3~4.6 

7.7~4.8 

7.8~4.6 

7.5~4.3 

7.4~4.2 

7.8~4.6 

7.6~4.5 

7.7~4.5 

C.O.P at 50% speed 

6.3 

6.4 

6.8   

6.6 

6.1 

6.1 

6.5 

6.5 

6.8   

Rated input 

power(kW) at air 15°C 

0.13~1.1 

0.17~1.2 

0.19~1.5 

0.22~1.73 

0.27~2.2 

0.3~2.6 

0.38~3.3 

0.57~3.8 

0.53~3.9 

0.62~5.2 

Rated input current(A) 

at air 15°C 

0.56~4.78 

0.74~5.2 

0.83~6.5 

0.96~7.52 

1.17~9.6 

1.3~11.3 

1.65~14.3 

2.48~16.5 

0.76~5.6 

0.89~7.4 

Power supply 

230V/1 Ph/50Hz 

400V/3 Ph/50Hz 

Advised water flux 

(m³/h) 

2~4 

2~4 

3~4 

4~6 

5~7 

6.5~8.5 

8~10 

10~12 

10~12 

12~18 

Sound pressure 1m 

dB(A) 

37.8~47.2 

38.8~48.2 

38.6~49.9 

42.1~50.7 

41.3~54.0 

43.1~53.8 

40.9~54.2 

43.5~54.9 

43.5~54.9 

42.6~54.7 

Sound pressure 10m 

dB(A) 

17.8~27.2 

18.8~28.2 

18.6~29.9 

22.1~30.7 

21.3~34.0 

23.1~33.8 

20.9~34.2 

23.5~34.9 

23.5~34.9 

22.6~34.7 

Water pipe in-out 

Spec    (mm) 

48.3

 

Net Dimension   

LxWxH (mm) 

961×340× 

658 

961×340× 

658 

961×340× 

658 

961×340× 

658 

961×340× 

658 

961×420× 

658 

961×420× 

758 

1092×420× 

958 

1092×420× 

958 

1161×530× 

958 

Net Weight      (kg) 

42 

45 

49 

50 

52 

63 

68 

90 

93 

120 

 

"

 

The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration system 
running at least 15 hours a day. 

"

 

Related parameters are subject to adjustment periodically for technical improvement without further notice. For 
details please refer to nameplate. 

Summary of Contents for GHD-150-0324

Page 1: ...Wellis Inverter Spa Heat Pump USER MANUAL...

Page 2: ...modes 3 1 4 Kind reminder 4 2 OPERATIONS 6 2 1 Notice before using 6 2 2 Operation instructions 6 2 3 Daily maintenance and winterizing 8 3 TECHNICAL SPECIFICATION 9 For users PLEASE READ IT CAREFULL...

Page 3: ...talled or removed by professionals and it is forbidden to dismantle and refit without permission b Don t put obstacles before the air inlet and outlet of the heat pump 2 Installation a This product mu...

Page 4: ...c The unit must be far away from any source of fire d Storage place must be bright wide open and good ventilation ventilation equipment is required 4 Maintenance Notice a If maintenance or scrap is re...

Page 5: ...mp will have ideal performance in the operation range Air 15 25 1 3 Advantages of different modes The heat pump has two modes Smart and Silence They have different advantages under different condition...

Page 6: ...ammable or turbid liquid 1 4 2 Don t lift the water union when moving the heat pump since the titanium heat exchanger inside the heat pump will be damaged 1 4 3 Don t put obstacles before the air inle...

Page 7: ...local dealer Don t try to repair the heat pump by yourselves 1 4 7 The main power switch should be out of the reach of Children 1 4 8 Please cut off the power in the lightning storm weather 1 4 9 Ple...

Page 8: ...longer service life please ensure water pump is on before heat pump starts to work and water pump is off after heat pump is off 2 1 2 Ensure no water leakage on piping system then unlock screen and p...

Page 9: ...ter inlet temperature Water outlet temperature for 3 seconds to lock screen and it will be dark for 3 seconds to unlock screen and it will be lit up Only after screen is unlocked any other buttons can...

Page 10: ...e last page 2 3 Daily maintenance and winterizing 2 3 1 Daily Maintenance Please don t forget to cut off power supply of the heat pump Please clean the evaporator with household detergents or clean wa...

Page 11: ...1 2 0 19 1 5 0 22 1 73 0 27 2 2 0 3 2 6 0 38 3 3 0 57 3 8 0 53 3 9 0 62 5 2 Rated input current A at air 15 C 0 56 4 78 0 74 5 2 0 83 6 5 0 96 7 52 1 17 9 6 1 3 11 3 1 65 14 3 2 48 16 5 0 76 5 6 0 89...

Page 12: ...Thank you for choosing Full inverter Pool heat pump Version C40Ir32...