background image

 

FOR USER

 

   

4.Defrosting 

a. Auto Defrosting: When heat pump is defrosting, 

  will be flashing. After defrosting, 

  will stop flashing.   

b. Compulsory Defrosting: When heat pump is heating, press   

  and 

  together for 5 seconds to start 

compulsory defrosting, and 

  will be flashing. After defrosting, 

  will stop flashing.   

(Note: Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for more 
than 10 minutes.)   
 

5.Wifi setting 

Please kindly check the last page. 

 

 

2.3. Daily maintenance and winterizing 

2.3.1. Daily Maintenance 
 

  Please don’t forget to cut off power supply of the heat pump 

!

 

Please  clean  the  evaporator  with  household  detergents  or  clean  water,  NEVER  use  gasoline, 
thinners or any similar fuel. 

!

 

Check bolts, cables and connections regularly. 

 
2.3.2. Winterizing 

 

In winter season when you don’t swim, please cut off power supply and drain water out of the 
heat pump. When using the heat pump under 2 , make sure

 there is always water flow. 

 

 

 

 

 

 
 
 
 
 
 

Important: 

Unscrew the water union of inlet pipe 
to let the water flow out. 
When the water in machine freezes in 
winter  season,  the  titanium  heat 
exchanger may be damaged. 

Summary of Contents for GHD-150-0324

Page 1: ...Wellis Inverter Spa Heat Pump USER MANUAL...

Page 2: ...modes 3 1 4 Kind reminder 4 2 OPERATIONS 6 2 1 Notice before using 6 2 2 Operation instructions 6 2 3 Daily maintenance and winterizing 8 3 TECHNICAL SPECIFICATION 9 For users PLEASE READ IT CAREFULL...

Page 3: ...talled or removed by professionals and it is forbidden to dismantle and refit without permission b Don t put obstacles before the air inlet and outlet of the heat pump 2 Installation a This product mu...

Page 4: ...c The unit must be far away from any source of fire d Storage place must be bright wide open and good ventilation ventilation equipment is required 4 Maintenance Notice a If maintenance or scrap is re...

Page 5: ...mp will have ideal performance in the operation range Air 15 25 1 3 Advantages of different modes The heat pump has two modes Smart and Silence They have different advantages under different condition...

Page 6: ...ammable or turbid liquid 1 4 2 Don t lift the water union when moving the heat pump since the titanium heat exchanger inside the heat pump will be damaged 1 4 3 Don t put obstacles before the air inle...

Page 7: ...local dealer Don t try to repair the heat pump by yourselves 1 4 7 The main power switch should be out of the reach of Children 1 4 8 Please cut off the power in the lightning storm weather 1 4 9 Ple...

Page 8: ...longer service life please ensure water pump is on before heat pump starts to work and water pump is off after heat pump is off 2 1 2 Ensure no water leakage on piping system then unlock screen and p...

Page 9: ...ter inlet temperature Water outlet temperature for 3 seconds to lock screen and it will be dark for 3 seconds to unlock screen and it will be lit up Only after screen is unlocked any other buttons can...

Page 10: ...e last page 2 3 Daily maintenance and winterizing 2 3 1 Daily Maintenance Please don t forget to cut off power supply of the heat pump Please clean the evaporator with household detergents or clean wa...

Page 11: ...1 2 0 19 1 5 0 22 1 73 0 27 2 2 0 3 2 6 0 38 3 3 0 57 3 8 0 53 3 9 0 62 5 2 Rated input current A at air 15 C 0 56 4 78 0 74 5 2 0 83 6 5 0 96 7 52 1 17 9 6 1 3 11 3 1 65 14 3 2 48 16 5 0 76 5 6 0 89...

Page 12: ...Thank you for choosing Full inverter Pool heat pump Version C40Ir32...

Reviews: