Starting up the device
Caution!
Please adhere to the operating instructions of
the connected devices.
Put the tool into operation as described in the
FKDSWHUÄ3ODFLQJLQWRRSHUDWLRQ³
Check to see if the mains voltage mat-
ches the ratings on the nameplate.
Make sure the machine is switched off before
plugging in.
After switching on the device, the microprocessor
carries out a self- test and reads out the values of
the parameters stored in the tool.
7KHVHWSRLQWWHPSHUDWXUHDQG¿[HGWHPSHUDWXUHV
are stored in the tool. The actual temperature
YDOXHLQFUHDVHVWRWKHVHWSRLQWWHPSHUDWXUH
VROGHULQJWRROLVKHDWHGXS
Soldering and desoldering
&DUU\RXWVROGHULQJZRUNDVGLUHFWHGLQWKHRSHUD
-
WLQJLQVWUXFWLRQVRI\RXUFRQQHFWHGVROGHULQJWRRO
Handling the soldering tips
Coat the selective and tinnable soldering tip with
VROGHUZKHQKHDWLQJLWXSIRUWKH¿UVWWLPH7KLV
removes oxide coatings which have formed
during storage and impurities from the soldering
tip.
Make sure that the soldering tip is well coated
with solder during breaks between soldering work
and prior to storage of the device.
'RQRWXVHDJJUHVVLYHÀX[LQJDJHQWV
$OZD\VPDNHVXUHWKDWWKHVROGHULQJWLSVDUH
¿WWHGSURSHUO\
Select as low a working temperature as possible.
Select the largest possible soldering tip shape for
the application.
5XOHRIWKXPEWKHVROGHULQJWLSVKRXOGEHURXJKO\
as large as the soldering pad.
Coat the soldering tip well with solder to ensure
WKDWWKHUHLVHI¿FLHQWKHDWWUDQVIHUEHWZHHQWKH
soldering tip and the soldering area.
Prior to extended breaks between soldering work,
VZLWFKRIIWKHVROGHULQJV\VWHPRUXVHWKH:HOOHU
function to reduce the temperature when the
soldering equipment is not in use.
&RDWWKHWLSZLWKVROGHUSULRUWRVWRUDJHLI\RXGR
not intend to use the soldering iron for an
extended period of time.
$SSO\VROGHUGLUHFWO\WRWKHVROGHULQJDUHDQRWWR
the soldering tip.
Change the soldering tips using the designated
tool.
'RQRWDSSO\PHFKDQLFDOIRUFHWRWKHVROGHULQJ
tip.
Notice
The control units have been adapted to hold a
medium-sized soldering tip. Discrepancies may
occur if the tip is changed or a different shaped
tip is used.
Overload cut-out
To avoid overloading the station, power output is
DXWRPDWLFDOO\UHGXFHGLQWKHHYHQWRIDQRYHUORDG