Continuous illumination indicates that the system is warming up.
Flashing light indicates that the preselected temperature has been
reached.
Note Please refer to the accessories section on page 16 for a list of tools
that can be connected to the WD 1 (M) / WD 1000.
6
Operating the device
6.1
Setting the temperature
Setting the temperature individually
1. Switch on the device at the mains power switch (7).
The display indicates the actual temperature value.
2. Press the UP or DOWN button.
The display switches to the preset setpoint value. The
temperature symbol (14) flashes.
3. Press the UP or DOWN button to set the desired setpoint
temperature:
-
Brief touching alters the setpoint value by one degree.
-
Permanent pressing alters the setpoint value in rapid pass
mode.
The actual value of the selected channel appears in the display
again approx. 2 seconds after the setting buttons are released.
4. Press the UP and DOWN buttons simultaneously.
If the channel is now inactive, "OFF“ appears in the display.
If the channel is now activated, the current actual temperature
appears in the display.
Stored data is not lost when a channel is switched off.
Selecting the temperature with temperature buttons I, II and III
The setpoint temperature value can be set by selecting three preset
temperature values (fixed temperatures).
Factory settings:
I = 150 °C (300 °F), II = 350 °C (662 °F), III = 380 °C (716 °F)
Press the required temperature button I, II or III.
The selected setpoint appears on the display for approx. 2 s. The
temperature symbol flashes while the setpoint is displayed.
The unit switches back to the actual value display automatically.
Setting the value of temperature buttons I, II and III
1. Press the required temperature button I, II or III.
2. Set the setpoint temperature value with the UP or DOWN button.
3. Press and hold the required temperature button I, II or III for three
seconds.
The temperature display for the corresponding temperature value
flashes during this period. The set value is stored after 3
seconds.
4. Release the temperature button again.
Summary of Contents for WD 1000
Page 1: ...EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT WD 1 M WD 1000 Betriebsanleitung DE ...
Page 17: ...EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT WD 1 M WD 1000 Operating Manual DE ...
Page 33: ...EN ES IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT WD 1 M WD 1000 Manual de uso DE ...
Page 52: ...WD 1 WD 1000 Exploded Drawing ...
Page 53: ...WD 1M WD 1000 Circuit Diagram DE EN FR IT ES PT NL SV DK FI GR TR CZ PL HU SK SL EE LV LT ...