6.  Plug the 3-pin foot switch into the rear of the unit ( 6 ).

7.  Insert the cartridge adapter in the air outlet ( 4 ) on the front of the unit and lock with

a clockwise 1/4 turn.

8.  Turn on the unit ( 3 ).

9.  Set the air pressure regulator ( 5 ) to the desired operating pressure.

10.  Operate the foot switch to initiate material flow. Release the foot switch to stop the

flow of material. 

KDS834A/KDS824A*

1.  Fit the quick-release coupling for the compressed air hose OD 6mm to the rear of the 

unit ( 10 ) / ( 13 )* (12 mm spanner).

2.  Connect filtered compressed air supply max. 7 bar with air hose OD 6mm 

( 10 ) / ( 13 )*.

Important: Check the compressed air system for damage and ensure that the 
compressed air hoses and couplings are seated properly. 
Protect the quick-release coupling for the air supply against twisting.

3.  Ensure that the unit is turned off.

4.  Set the slide switch ( 12 ) / ( 15 )* to the correct mains supply voltage.

5.  Connect up the mains lead ( 13 ) / ( 16 )*.

6.  Plug the 3-pin foot switch into the rear of the unit ( 9 ) / ( 12 )*.

7.  Insert the cartridge adapter in the air outlet ( 5 ) / ( 10 )* on the front of the unit and

lock with a clockwise 1/4 turn.

8.  Set the timer control switch ( 6 ) / ( 8 )* to 

”TIMED” for automatic timer control, or 
”MANUAL” for manual timer control.

9.  For automatic timer control the length of the dispensing pulse can be set on the 

4-digit decimal push-buttons ( 2 ) / ( 3 )*. Range of adjustment 0.01 – 99.99 sec. 
Set the air pressure regulator ( 4 ) / ( 1 )* to the desired operating pressure.

10.  Turn on the unit ( 7 ) / ( 11 )*. 

11.  Operate the foot switch.

With 

automatic timer control

 the foot switch can be released again immediately. The material 

flow time is controlled automatically by the TIMER.

With 

manual timer control

 the material flows for as long as the operator depresses the 

foot switch. This mode is recommended when varying quantities of material have to be 
dispensed in succession.

The length of the dispensing pulse is indicated by a green LED ( 8 ) / ( 4 )*.

Using the vacuum function

The KDS808/834A/824A* dispensing systems incorporate a vacuum system. This vacuum is 
present at the cartridge during the intervals between dispensing and prevents uncontrolled 
dripping by low viscosity materials after the dispensing pulse.

The vacuum has infinitely variable adjustment, and is increased by turning the vacuum knob 
( 2 ) / ( 1 ) / ( 5 )* in the direction of the arrow or counterclockwise. The vacuum should be 
as low as possible depending on the viscosity of the medium.

Important: Foreign bodies must not enter through the vacuum system as this will 
clog or damage it.

Compressed air port for accessories (KDS824A only)

The KDS824A dispensing system features a separate compressed air duct. The outlet pressure 
can be adjusted from 0 - 7 bar with the right-hand pressure regulator ( 7 ). The set compressed 
air is permanently present at the outlet ( 9 ) and has no control function.

Summary of Contents for Kahnetics KDS808

Page 1: ...KDS808 KDS834A KDS824A Weller Logo_2011 in Weller Blau 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...KDS808 1 Pressure gauge for air outlet 2 Anti drip vacuum adjuster 3 Power switch 4 Air outlet for cartridge 5 Pressure regulator for air outlet...

Page 3: ...KDS808 6 Foot switch socket 7 Coupling for external air supply 8 0 5A fuse 9 Voltage selector switch 10 Power socket...

Page 4: ...drip vacuum adjuster 2 Time setting in sec 3 Pressure gauge for air outlet 4 Pressure regulator for air outlet 5 Air outlet for cartridge 6 MANUAL TIMER mode selector 7 Power switch 8 Indicator for di...

Page 5: ...KDS834A 9 Foot switch socket 10 Coupling for external air supply 11 0 5A fuse 12 Voltage selector switch 13 Power socket...

Page 6: ...et 3 Time setting in sec 4 Indicator for dispensing pulse 5 Anti drip vacuum adjuster 6 Pressure gauge for Accessories air outlet 7 Pressure regulator for Accessories air outlet 8 MANUAL TIMER mode se...

Page 7: ...KDS824A 12 Foot switch socket 13 Coupling for external air supply 14 0 5A fuse 15 Voltage selector switch 16 Power socket...

Page 8: ...spenser with an integral pressure regulator from 0 7 bar and pressure gauges Adjustable vacuum prevents dripping by the dispensed medium Digital timer control for repeatable dispensed quantities Dispe...

Page 9: ...it decimal push buttons 2 3 Range of adjustment 0 01 99 99 sec Set the air pressure regulator 4 1 to the desired operating pressure 10 Turn on the unit 7 11 11 Operate the foot switch With automatic t...

Page 10: ...sure regulator Use a dispensing needle with a different diameter For units with timer control change the timer setting The first dispensing pulses after a cartridge change can produce different amount...

Page 11: ...nd enclosed place out of the reach of children 6 Do not overload the device Operation is better and safer within the specified power and pressure range 7 Use the right device for the job Do not use a...

Page 12: ...centre provided that no other instructions are given in the operating instructions 18 Attention Only use accessories or auxiliary devices that are listed in the accessories list found in the operating...

Page 13: ......

Page 14: ...5 1 I 110 220 I lP3 I 4 L D2 YCC a o 470 1l7 ol 1lt 119 lit 1 I i M 22D ol 1lt m 1 i 10 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentD...

Reviews: