12
Dimensions (in.)
Draw down
(Gallons)
Tank
Volume
Gallons Diameter Height
30/50psi
7.6
11
22
2.4
10.3
15
18
3.2
14.0
15
22
4.3
14.0
15
25
4.3
20.0
15
32
6.2
26.0
15
39
8.0
32.0
15
47
9.9
34.0
22
30
10.5
44.0
22
36
13.6
62.0
22
47
19.2
86.0
26
47
26.6
e. Note: Draw down as expressed in gallons is not equal to the
tank capacity expressed in gallons; draw down is less.
Therefore, the need for a larger or additional tank for additional
draw down volume in the system may be necessary.
Be aware: You may encounter “cycle stop” valves on the market,
which some manufacturers imply produce an effect similar to a
Variable Frequency Drive (or “VFD”), but at a far lower cost.
Don’t be fooled, as they are not equal! In fact, a cycle stop valve
will cause the well pump to consume more energy than it
otherwise would. Cycle stop valves are not appropriate for the low
flow rates required by the Well-Connect and should not be used for
this application.