2.
Lay the Essentials™ Gas Sampler on a smooth, clean surface.
3.
Undo the enclosure clasps and open the enclosure door (
).
Figure 4: Opening the Enclosure
4.
If applicable, turn the knobs on the front panel counterclockwise to loosen them, and then open the front panel (
Gauge Assembly
5.
Wrap the exposed threads on the gauge assembly with PTFE tape (
).
6.
Install the gauge assembly to purge valve B (
).
Figure 5: Installing the Gauge Assembly
7.
Using a crescent or pipe wrench, tighten the gauge assembly. Ensure that the pressure gauge face is upright and that
the tube elbow is on top.
9
IOM-222
MODEL: ESSENTIALS™ GAS SAMPLER
REV: A
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331