6-1. General trouble shooting
No
Problem
Cause
Solution
1
Power Indication lamp does
not on after switch on the main
switch
Loose contact at input lead
Check contact
situation
Lamp malfunction, poor contact
Check contact
situation. Replace
lamp
Main switch malfunction
Check switch,
replace if necessary
2
Cooling fan
stops to rotate
after machine
has worked a
period
Power
indication
lamp on
Cooling fan blade blocked by
obstacle.
Clear
Cool fan failure
Check fan, replace if
necessary
Power
indication
lamp off
See No. 1
3
Overheat light on
Work excess the rate duty circle
Use under rate duty
circle
Input voltage is too high
Use under rate input
voltage
4
The mains power circuit
breaker or fuse nuisance trip
High ambient temperature
Use machine under
rated ambient
temperature
Using an extension cable
Use extension cable
according to section
4-6