2.20 Electrical 

Power

2.21  Power Source Review
 

Review the power source and the voltage rating on the units serial number tag to be sure 
they agree in voltage, phase and frequency. Serious damage may occur to the system if it is 
connected to an improper voltage. All Welch systems must be grounded. Grounding reduces 
the risk of electric shock in the event of an electrical short circuit. The plug must be plugged 
into an outlet properly grounded. Consult your local electrical codes if you have doubts.

2.22 Overload 

Protection

 

The motor manufacturer makes motor thermal overload protection available as an aid to 
minimize motor failure. Overload protection is a standard feature on both 50/60Hz single-
phase motors. The motors have automatic overload protection. Automatic reset protection is 
designed to reset itself after a predetermined cooling period. If the fault to the drive remains 
unaltered, the motor will cycle on and off until fault is corrected.

2.23 Identifi cation Symbols:

 Power Off 

 Power On

2.24 Grounding 

Instructions

 

This product should be grounded. In the event of an electrical short circuit, grounding reduces 
the risk of electric shock by providing an escape wire for the electric current. This product 
is equipped with a cord having a grounding wire with a grounding plug. The plug must be 
plugged into an outlet that is properly installed and grounded in accordance with all local codes 
and ordinances. This adapter shown in Figure B and Figure C is not acceptable in Canada.

   

DANGER

Improper installation of the grounding plug can result in a risk of 

electrical shock. 

 

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to 
either fl at blade terminal. The wire with insulation having an outer surface that is green with or 
without yellow stripes is the grounding wire. Check with a qualifi ed electrician or serviceman 
if the grounding instructions are not completely understood, or if in doubt as to whether the 
product is properly grounded. Do not modify the plug provided; if it will not fi t the outlet, have 
the proper outlet installed by a qualifi ed electrician.

Summary of Contents for 2562B-01

Page 1: ...r organic vapors or gases Warning Be sure to properly identify intake and discharge before using pump See section 2 5 Part No 642518D Printed in USA Welch Ilmvac 5621 W Howard Street Niles IL 60714 Ph...

Page 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units conform to the SI International system of units of measureme...

Page 3: ...Specifications 3 01 Specification Chart Section 04 Motor Power Specifications Features 4 01 Motor Specification Chart 4 02 Changing the Voltage Settings for Global Motor Option on A Models 4 03 Changi...

Page 4: ...e potential of the pump head bursting and causing possible injury to personnel in the area I 17 All electrical products generate heat To avoid serious burns never touch unit during or immediately afte...

Page 5: ...e contact The pump should be located as closely to its system as possible in order to utilize it most efficiently The pump is rated for indoor use only Maximum altitude 2000 meters Operating temperatu...

Page 6: ...Identification Symbols Power Off Power On 2 24 Grounding Instructions This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by provi...

Page 7: ...nly used to indicate vacuum level when operating in the rough vacuum range 0 to 29 9 InHg Dial vacuum gauges give negative pressure that is pressure below atmospheric The reference point for the gauge...

Page 8: ...is if you have droplets coming out of the exhaust port If you see droplets of water Welch recommends you use a cold trap to capture the water before entering the pump or dilute the water vapor stream...

Page 9: ...3 13 Leak Detection The importance of eliminating all leaks in a vacuum system is obvious The pump must remove this added volume of leaked gas to maintain the desired vacuum Leaks for these pumps can...

Page 10: ...d A simple criterion for the condition of the pump is the determination of its maximum vacuum capability This can be accomplished by blocking of the intake and reading the vacuum level on the gauge Se...

Page 11: ...NPT 3 8 Weight lbs 16 5 Kg 7 5 Overall Dimensions L in Inches cm 17 0 43 2 W in Inches cm 7 5 19 1 H in Inches cm 12 0 30 5 Shipping Weight lbs 24 Kg 10 9 Shipping Dimensions L in Inches 21 5 W in Inc...

Page 12: ...12 6 11 Pumping Speed Curves...

Page 13: ...6 12 Dimensional Drawing 244 0 CORD ASSY 8 25 4X 8 32 UNC 2B THRU 7 09 6 67 9 45 INTAKE NIPPLE FOR 3 8 TUBING MUFFLER 11 67 OUTLET INLET 182 6 3 50 5 38 7 19 296 4 240 0 209 5 9 61 180 0 169 4 88 9 13...

Page 14: ...1 2 666544 Connecting Rod Ass y 2 2 2 621755 502 Valve Plate Ass y 2 3 2 623071 O Ring Cylinder 2 2 4 2 623143 O Ring Valve Plate 2 2 5 2 641255 Exhaust Muffler 2 1 6 6 625175 Head Screw 6 7 2 624496...

Page 15: ...An inlet trap to help prevent ingestion of fluids into the pump a dial gauge for continuous vacuum level monitoring and a vacuum regulator to adjust vacuum levels Just plug it in and you re up and ru...

Page 16: ...pressed or implied The method of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Welch Ilmvac Vacuum pumps that have been operated within a vacuum syst...

Reviews: