Section 7: APPLICATION INFORMATION

 
7.20  Vacuum System for Vacuum Chamber, Glove Box, Annular Space & Transfer Line:
 - 

2562B-01

 - 

2562C-05

 - 

2562C-56

 
7.21  System Components *

2562C-01

2562C-56

Qty.

Description for regulator / separator jar

*

1

Jar Assembly

*

1

Needle Valve Miniature

*

1

Instrument Knob

*

1

Hose Barb, 3/8” NPT

*

1

Hose Barb Fitting

*

1

Hose Barb, Male Straight Kynar

*

1

Vacuum Gauge InHg.

*

1

Jar Gasket

*

1

Plastic Jar

*

1

Hex Nipple

* System components available as kit Cat. No. 2565K-50, vacuum regulator with separator jar.

7.22  Vacuum System for Cell Harvesting:
 

Welch’s new portable oil-free general utility roughing pumps provide continuous, reliable 
vacuum that your vacuum chamber, glove box, annular space and transfer line applications 
require. The pumping mechanism is an economical twin head oil-free Wob-L® known for 
reliability and durability. These rugged pumps handle 20,000 plus roughing cycles – from 
atmospheric to 5 Torr – before needing seal maintenance.

 

The pumps come completely equipped and ready to use. An inlet trap to help prevent ingestion 
of fl uids into the pump, a dial gauge for continuous vacuum level monitoring, and a vacuum 
regulator to adjust vacuum levels. Just plug it in and you’ re up and running.

 
 

Choose Model 2581B-50 for evacuating vacuum ovens, annular spaces, transfer lines and 
purging a glove box up to 30 cubic feet. For Vacuum Ovens, Model 2561B-50 is suited for 1.5 
cubic foot ovens or smaller and Model 2581B-50 can be used for up to 3.5 cubic feet. 

 
 

The pumping speed of the 2561 and 2581 at rough vacuum levels is equal to oil-seal rotary 
vane pumps of similar size. This makes the 2561 and 2581 an economical, oil-free solution 
for replacing oil-seal rotary vane pumps. These pumps are therefore highly recommended for 
standard duty laboratory applications, general vacuum work and where quick roughing of a 
chamber is needed.

 
 

The 2581 and 2561 pump Models are for use in standard duty applications. This means that 
they are not recommended for pumping acidic, basics or organic vapors or gasses. If you are 
looking for a pump to handles these types of conditions, contact a Welch representative and 
they will be able to assist you in selecting the correct pump for your application.

Summary of Contents for 2562B-01

Page 1: ...r organic vapors or gases Warning Be sure to properly identify intake and discharge before using pump See section 2 5 Part No 642518D Printed in USA Welch Ilmvac 5621 W Howard Street Niles IL 60714 Ph...

Page 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units conform to the SI International system of units of measureme...

Page 3: ...Specifications 3 01 Specification Chart Section 04 Motor Power Specifications Features 4 01 Motor Specification Chart 4 02 Changing the Voltage Settings for Global Motor Option on A Models 4 03 Changi...

Page 4: ...e potential of the pump head bursting and causing possible injury to personnel in the area I 17 All electrical products generate heat To avoid serious burns never touch unit during or immediately afte...

Page 5: ...e contact The pump should be located as closely to its system as possible in order to utilize it most efficiently The pump is rated for indoor use only Maximum altitude 2000 meters Operating temperatu...

Page 6: ...Identification Symbols Power Off Power On 2 24 Grounding Instructions This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by provi...

Page 7: ...nly used to indicate vacuum level when operating in the rough vacuum range 0 to 29 9 InHg Dial vacuum gauges give negative pressure that is pressure below atmospheric The reference point for the gauge...

Page 8: ...is if you have droplets coming out of the exhaust port If you see droplets of water Welch recommends you use a cold trap to capture the water before entering the pump or dilute the water vapor stream...

Page 9: ...3 13 Leak Detection The importance of eliminating all leaks in a vacuum system is obvious The pump must remove this added volume of leaked gas to maintain the desired vacuum Leaks for these pumps can...

Page 10: ...d A simple criterion for the condition of the pump is the determination of its maximum vacuum capability This can be accomplished by blocking of the intake and reading the vacuum level on the gauge Se...

Page 11: ...NPT 3 8 Weight lbs 16 5 Kg 7 5 Overall Dimensions L in Inches cm 17 0 43 2 W in Inches cm 7 5 19 1 H in Inches cm 12 0 30 5 Shipping Weight lbs 24 Kg 10 9 Shipping Dimensions L in Inches 21 5 W in Inc...

Page 12: ...12 6 11 Pumping Speed Curves...

Page 13: ...6 12 Dimensional Drawing 244 0 CORD ASSY 8 25 4X 8 32 UNC 2B THRU 7 09 6 67 9 45 INTAKE NIPPLE FOR 3 8 TUBING MUFFLER 11 67 OUTLET INLET 182 6 3 50 5 38 7 19 296 4 240 0 209 5 9 61 180 0 169 4 88 9 13...

Page 14: ...1 2 666544 Connecting Rod Ass y 2 2 2 621755 502 Valve Plate Ass y 2 3 2 623071 O Ring Cylinder 2 2 4 2 623143 O Ring Valve Plate 2 2 5 2 641255 Exhaust Muffler 2 1 6 6 625175 Head Screw 6 7 2 624496...

Page 15: ...An inlet trap to help prevent ingestion of fluids into the pump a dial gauge for continuous vacuum level monitoring and a vacuum regulator to adjust vacuum levels Just plug it in and you re up and ru...

Page 16: ...pressed or implied The method of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Welch Ilmvac Vacuum pumps that have been operated within a vacuum syst...

Reviews: