Programming the Scanner 4–15
Table 4.6 Industrial Symbologies
Symbology
Codabar
Code 39
I 2 of 5
Code 128
Options
Start/stop transmit, check character
transmission, concatenation
Start/Stop transmit, check character
transmission, full ASCII, symbol
appendation
Check digit, check digit (even #’s
only) transmission
None
01
00
02
01
Min
Max
Length
60
48
80
80
Example:
Configure the SCANTEAM 3700PDF to decode the following
symbologies:
Code 39:
Minimum Length = 8
Maximum Length = 14
Start/Stop:
Transmit
Check Digit:
Required
Check Digit:
Transmit
Full ASCII:
Yes
Code 128:
Minimum Length = 6
Maximum Length = 12
Refer to the Selections/Variables options on the CODE Selection I (Industrial) page of
the SCANTEAM PDF417 Programming Menu.
Note:
If Check Digit is required and the code does not contain a check digit, the SCANTEAM
3700 will not read the code.
The scanning sequence to program the scanner to read these Code 39 and Code 128
formats would be:
FUNCTION
SELECTION
VARIABLE
Enter Menu Page
ENTER
Set DEFAULT Values
DEFAULT
Set Code 39
II
Scanning sequence continued on next page.