23
Original instructions.
INSTALLATION AND START UP
· Electrical connection checklist
DANGER!
If the mains cable or plug is damaged,
it must be replaced by the manufac-
turer, its service agent or similarly
qualified persons in order to avoid a
hazard.
1.
The machine should only be connected to the power supply by qualified personnel. The
following safety instructions should be obeyed at all times.
2. Ensure that the electrical requirements stated on the TECHNICAL SPECIFICATIONS and on
the ratings plate located under the drip tray inside the machine match the specifications of
the power supply.
3. Ensure that the domestic electrical supply where the machine is being installed is rated for
and able to provide
the power required by the machine. Insufficient power supply, wiring,
grounding, or insulation can result in overheating and possibility of fire.
4.
The coffee machine must be connected to an earth grounded electrical outlet that complies
with the regulations in force in the country of installation.
For appliances not fitted with a
supply cord and a plug, means for disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
5. Ensure that a circuit breaker engineered for the power consumption of the machine is
installed to protect the electrical supply, as specified on the ratings plate located under the
drip tray.
6. Never connect the machine to the power supply via extension cords, plug adapters, or
shared outlets.
Important:
The manufacturer will not be held liable for
damage to persons, animals or property
resulting from incorrect installation of the
coffee machine
.
Machine:
230Vac Ph+N
Blue
Brown
NEUTRAL
PHASE
Yellow/Green
Supply cable