8.
13
1
6
7
8 12 11 10
14
10
11
12
8
9
13
C
D
B
A
EM
ER
G
EN
C
Y
ST
O
P
2
4
5
3
1
6
7
A.
LOW WATER INDICATOR LIGHT (RED)
When lit, indicates that the kettle is low on water and will not
operate in this condition. This will also light when the kettle is
tilted.
B.
ON-OFF SWITCH/SOLID STATETEMPERATURE
CONTROL
Turns kettle ON/OFF and allows the operator to adjust the
kettle temperature in increments from 1 (Min.) to 10 (Max.).
C.
HEAT INDICATOR LIGHT (GREEN)
When lit, indicates that the kettle's burner is on .Cycles ON-
OFF with burner.
D.
VACUUM/PRESSUREGAUGE
Indicate steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.
1.
MAIN POWER SWITCH
Power switch for unit.
2.
MIX/LIFT SWITCH
Sets hydraulics to mix or lift mode.
3.
UP/DOWN SWITCH
When unit is in lift mode, mixer bridge can be raised or
lowered with this switch.
4.
MIXER SPEED CONTROL
Controls speed of agitators and mixer bridge lift.
5.
EMERGENCY STOP BUTTON
Stops hydraulic system (agitators and mixer bridge lift).
6.
HEAT/COOL SWITCH
Switches left hand kettle from heating to cooling.
7.
HEAT/COOL SWITCH
Switches right hand kettle from heating to cooling.
8.
ACTIVE/BYPASS SWITCH
Switch to activate or bypass (manual operation) the
controller.
9.
TEMPERATURE CONTROLLER
Digital temperature control and indicator.
10. WATER METER POWER SWITCH
Power switch for water meter.
11. WATER METER START SWITCH
Starts water flow to kettle.
12. WATER METER INTERRUPT SWITCH
Interrupts flow without resetting water meter.
13. WATER METER CONTROL
Display and settings for water meter.
14. TIME/TEMPERATURE CHART RECORDER
Documents cooking information.
OPERATING CONTROLS AND INDICATORS
OPERATING INSTRUCTIONS
WARNING
If for any reason this unit is not
functioning correctly DO NOT
OPERATE. Contact your
authorized service agent.
!