6.
GAS
ENSURE THE GAS SUPPLY MATCHES THE KETTLE'S
REQUIREMENTS AS STATED ON THE RATING PLATE.
Installation must conform, with local codes or in the absence
of local codes, with the National Fuel Gas Code ANSI
Z223.1/NFPA 54, or the Natural Gas and Propane Installation
Code, CSA B149.1.
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psi (3.45 kPa).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.45 kPa).
It is recommended that a sediment trap (drip leg) be installed
in the gas supply line. If the gas pressure exceeds 1/2 psi
(3.45 kPa) water column, a pressure regulator must be
installed, to provide a maximum of 1/2 psi (3.45 kPa) water
column gas pressure to the gas control valve.
Use a gas pipe joint compound which is resistant to L.P. gas.
Test all pipe joints for leaks.
1.
Removed supplied manual shut-off valve and establish
mounting location.
2.
Add union and
piping as required.
3.
Connect the gas
line to the manual
shut-off valve.
ELECTRICAL
ENSURE THE ELECTRICAL SUPPLY MATCHES THE
KETTLE'S REQUIREMENTS AS STATED ON THE RATING
LABEL.
Install in accordance with local codes and/or the
National Electric Code ANSI/NFPA No 70-1981 (USA) or
the Canadian Electric Code CSA Standard C22.1
(Canada). A separate fused disconnect switch must be
supplied and installed. The kettle must be electrically
grounded by the installer.
The electric supply must match the power requirements
specified on the kettle's rating plate. The copper wiring
must be adequate to carry the required current at the
rated voltage. Refer to the specification sheet for
electrical specifications.
1.
Ensure main power is turned off before connecting
wires.
2.
Remove the screws at the rear of the center
console cover, and remove the cover. A wiring
diagram is affixed to the underside of the console
cover.
3.
Feed permanent copper wiring 18" through the cut-
out in the bottom of the console. Connect wiring in
junction box in the bottom of the console.
B
A
C
K
O
F
K
E
T
T
L
E
UNION
NIPPLE
SHUT-OFF
VALVE
GAS
SUPPLY
4.
Turn main power back on.
5.
Check for correct rotation of electric motor (access
by removing top front cover on center console). If
rotation is incorrect, disconnect main power and
reverse any two of the three live lines.
6.
Replace the console cover and secure it with
screws.
FOR POWER TILT UNITS ONLY
NOTE: Ensure the electrical supply matches the kettle's
requirements as stated on the rating label.
This kettle is built to comply with CE standards. Many local
codes exist, and it is the responsibility of the owner and
installer to comply with these codes.
CLEANING
After installation the kettle must be thoroughly cleaned and
sanitized prior to cooking.