Installation and operating instructions
Fresh water station WHI freshaqua 22
2 Safety
83514302 ▪ 1/2017-08 ▪ Ext. PAW
5-32
2
Safety
2.1
Designated use
The fresh water station must only be installed in heating systems between the buffer tank
and the domestic water circuit. Due to its construction, it must only be installed and
operated in a vertical position. The technical limit values specified in this instruction must
be considered.
Use only original accessories in connection with the fresh water station.
Using the station contrary to its designated use will invalidate all liability claims.
The wrapping materials are made of recyclable materials that can be recycled by
standard recycling operations.
2.2
Safety instructions
The following must be observed during installation and commissioning:
Relevant local and national regulations
Accident prevention regulations of the employers' liability insurance association
Instructions and safety instructions mentioned in these instructions
WARNING
Risk of scalding from hot water!
Due to the third party circulation, up to 90 °C hot water may run
out at the tapping point in the primary circuit.
No external pump may be installed between the fresh
water station and the buffer tank.
The fresh water station must not be connected to a
heating circuit distributor.
CAUTION
Risk of burns!
The valves and fittings and the pumps can become heated up to
more than 95 °C during operation.
The insulation must remain closed during operation.