33
Temperature
Humidity
Requirements for EMC
Low voltage guideline
In operation:
max. 80% rel. humidity
Guideline 89/336/EEC
Guideline 72/23/EEC
-15°C to +40°C
no dew point
EN 50081-1
EN 60335
Transport / storage:
EN 50082-1
-20 to +70°C
8.4 Electrical data
8.5 Permitted ambient conditions
WG10…/1-C
Mains voltage _______________________________ 230 V
Mains frequency __________________________ 50/60 Hz
Consumption- Start _______________________ 0·290 kW
- Operation __________________ 0·150 kW
Operating current ____________________________ 1·1 A
External fusing ___________________________ 16 A slow
Internal fusing ____________________________ 6·3A slow
8.3 Permissible fuels
Natural gas E
Natural gas LL
Liquid petroleum gas B / P
The capacity graph is in accordance with EN 676. There is
a rating reduction dependent on the altitude of the
installation: approx. 1% per 100 m above sea level.
8 Technical data
8.1 Burner equipment
8.2 Capacity graphs
Burner
Combustion Motor
Servomotor
Ignition
Gas pressure Air pressure Flame
type
manager
unit
switch
switch
sensor
WG10…/1-C,
W-FM 10
ECK 03/F-2/1
W-STD 4·5
W-ZG01
GW50 A5/1
LGW 10/A2
Ionisation
vers. Z-LN
230V, 50Hz
2870 r.p.m.
0·13 kW, 1·0 A
Cond. 4
µ
F
Burner type
WG10…/1-C
Combustion head
WG10-C
Heat rating
25...110 kW
Combustion c
hamber pr
essur
e [mbar]
Combustion heat rating [kW]
2·5
2·0
1·5
1·0
0·5
-0·5
-1·5
Summary of Contents for WG10 1-C Series