- 7 -
SHUT DOWN welding power source, disconnect input power employing
lockout/tagging procedures.
Lockout/tagging procedures consist of padlocking line disconnect switch in open
position.
Removing fuses from fuse box, or shutting off and red-tagging circuit breaker or
other disconnecting device.
1.4
.
Power Supplier Requirements
Input volt must be standard sine wave, effective value 380V
±
10%, frequency
50Hz.
Unbalance degree of 3-phase volt must be no more than 5%.
Power supply:
Table 3: Power supply connection
Note: The size of fuse and breaker in the table are for reference only.
Model
WM250FI
WM350FI
WM500FI
Power supply
3 phase AC 380V
Min. capacity
Power network
12KVA
26KVA
45KVA
Generator
16KVA
34KVA
60KVA
Input volt protection
Fuse
20A
30A
50A
Circuit breaker
20A
32A
63A
Cable size
(cross-section)
Input volt
≥1.5mm
2
≥2.5mm
2
≥4mm
2
Output volt
25mm
2
35mm
2
50mm
2
Ground lead
≥1.5mm
2
≥2.5mm
2
≥4mm
2