Page 1: ... in mind However your overall safety can be increased by proper installation and thoughtful operation in your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And most importantly think before you act and be careful C V A N U G R A H D U T A N I A G A Jln Arief Rahman Hakim 51 Komplek Ruko 21 Klampis Blok D 1 Telp 031 ...

Page 2: ... 1 Index 1 Principle Technical data 1 2 Installation Guide 4 3 Repair Maintenance 7 Appendix A EMC Suggestion for installation and use of welder 10 Appendix B Feedback Form 12 ...

Page 3: ... After this process the welder s dynamically responsive speed has been greatly increased so the welder size and weight are reduced noticeably Power source enjoy sound anti fluctuating ability and high quality performance during external context changes Easy to arc start stable arc length pretty weld formation and capability of continuous adjusting the welding current 54 U V I A U 20 0 04I Imin Ima...

Page 4: ...8 4 31 32 5 41 6 43 5 Rated duty cycle 25 60 60 50 Rated output open load voltage V 9 Range of output current A 20 180 20 200 20 250 Range of output voltage V 20 8 27 2 20 8 28 20 8 30 MMAArc force current A 50 100 MMA arc striking current A 50 Protection class IP21 Insulation class F Cosφ 0 98 Efficiency 80 Cooling style Air blast cooling Weight Kg 9 5 Dimension L W H mm 389 155 299 Table 1 FARC ...

Page 5: ...审 核 工 艺 批准 共 张 第 张 比例 重量 阶 段 标 记 质 量 B T1 RB1 RB2 C12 R9 _ C11 R7 C11 R8 AP1 Power Source Control Circuit AP6 C6 R2 C5 R1 CE1 RD 1 RE1 C1 Front Panel AP5 AP4 Power S upply R6 C10 SF1 KF1 KF2 C4 C3 R4 C8 R5 C9 R3 C7 KF4 KF3 C14 C15 EMC Capa citor CE seiers machine EMC Filter CE seiers machine GQ Thermal Swi tch 15 V 1 5 V VRD TB1 RA 1 TA ...

Page 6: ...an body and the insulation properties of accessories Environments with adverse conditions do not include places where electrically conductive parts in the near vicinity of the operator which can cause increased hazard have been insulated The gradient of ground must be no more than 10 Ensure no wind at the welding position or use screen to block the wind The distance between welder and wall must be...

Page 7: ...position Removing fuses from fuse box or shutting off and red tagging circuit breaker or other disconnecting device 1 4 Power Supply Requirements Input volt must be standard sine wave effective value 230V 10 and frequency 50 60Hz Unbalance degree of 1 phase volt must be no more than 5 Power supply Product type FARC200 Power Supply 1 phase AC 230V 10 50 60Hz Electricity Grid min capacity 7 5KVA Inp...

Page 8: ... firmly 3 Machine Assembling Guide 1 Connect the welding cable firmly 2 Turn on the power switch of the welding machine 3 Connect the input 1 phase power supply cable with the switchboard switch on Attention Cut off the power supply before connecting the welding cable Put the plug into the socket and then turn it clockwise to ensure good connection between the plug and socket ...

Page 9: ...ion acts At this point let the machine runs under open load for a few minutes and it will be automatically recover Under high temperature if work with large current for long period welder may shut down automatically due to air switcher trips Cut off the power supply to the electricity switchboard on frame and wait for 5 minutes to turn on the air switcher on the power source fist then connect the ...

Page 10: ...firmly Check if the welding cables are connected correctly and firmly Check if gas regulator is in good situation and gas flows out normally WARNING Have a qualified electrician do the maintenance and trouble shooting work Turn the input power off using the disconnect switch at the fuse box before working inside the machine Don t open up case uninstructed the max volt inside machine is 400V Never ...

Page 11: ...ne and turn on again after 1 minute 2 Check the connection of ground cable 3 Replace 3 Circuit breaker on the switchboard trips while in welding 1 The following devices may be damaged MOSFET Output diode module etc 2 Pulse drive board is damaged 3 Input rectifier bridge is damaged 1 Check and replace 2 If MOSFET is damaged check if Resistor 10Ω 3KΩ and Voltage regulator tube IN4148 3V are damaged ...

Page 12: ...ng area The following shall be taken into account 1 Other supply cables control cables signaling and telephone cables above below and adjacent to the arc welding equipment 2 Radio and television transmitters and receivers 3 Computer and other control equipment 4 Safety critical equipment for example guarding of industrial equipment 5 The health of the people around for example the use of pacemaker...

Page 13: ...nts bonded to the word piece will increase the risk that the operator could receive an electric shock by touching these metallic components and the electrode at the same time The operator should be insulated from all such bonded metallic components 5 Earthling of the work piece Where the work piece is nor bonded to earth for electrical safety nor connected to earth because of its size and position...