23
1.3
Capacity:
RO, ROH – Approximately 6 quarts (5.7 L)
R11 – Approximately 2 quarts (1.9 L)
2200 – Approximately 4 quarts (3.8 L)
1.4
Oil change schedule:
NOTE: Recommend using a 13/16” 8 point socket to remove the oil
drain plugs.
See maintenance timetable in Section IV, B.
The schedule time intervals should be shortened for conditions of dust,
dirt and moisture.
CAUTION: Do not mix oils. Oil incompatibility may cause bearing
failure.
2.
GREASE LUBRICATED (RG)
2.1
Factory Lubrication:
The bearings are packed with grease at the factory and ordinarily will
require no attention before starting provided the pump has been stored
in a clean, dry place prior to its first operation.
2.2
Approved Greases
Do not use any grease that is not listed unless it is approved by the
factory. Failure to comply may result in voiding the warranty.
2.3
Approved Substitute Greases for SRI No. 2.
NOTE:
The pump is lubricated at the factory with Chevron SRI No. 2.
APPROVED GREASE
BASE
MATERIAL
NLGI NO.
Chevron
SRI No. 2
(Preferred Grease)
Polyurea
2
Chevron
BRB No. 2
Polyurea
2
Exxon & Esso
UNIREX No. 2
Lithium
2
Texaco
RB
Lithium
2
Amoco
Rykon Premium 2
Lithium
2
Mobil
Mobilith 22
Lithium
2
Shell
Albida LC EP2
Lithium
2
Royal Purple
Ultra Performance
Aluminum
Complex
2
CAUTION: DO NOT MIX GREASES. GREASE INCOMPATIBILITY