© weinor GmbH & Co. KG
6 | EN
Rain function
The integrated rain sensor in the BiSens SWR-230V
measures the rain volume and compares it to the threshold
value.
CAUTION!
Caution - Very Hot! Risk of burns if touched!
The rain sensor is hot when operating!
Do not touch the rain sensor!
Requirement
The blind is retraced.
The measured rain value exceeds the set threshold value.
↓
↓
↓
15 -
17 min.
sensor drying phase
The blind moves up and remains raised for 15 to 17 minutes.
Red alarm LED lights steadily.
The travel keys at the device are blocked.
The red alarm LED
fl
ashes during the delay time.
After 15 to 17 minutes, the drive may be retracted via the
automatic transmitter.
Retracting via the hand-held transmitter is possible at any
time.
If the blind was retracted via a transmitter within the blocked
period (15 to 17 minutes), automatic raising of the system
in case of rain will be possible at the earliest one hour after
retraction.
Checking the rain function (test mode)
Requirement
The blind is retraced.
In the test mode the delay times are shortened from minutes
to seconds. In this way, the travel movements of the system
can be tested when the set threshold value is exceeded or
undercut.
1. Press and hold the UP button for at least 3 seconds until
the green operating LED
fl
ashes.
WARNING!
Risk of injury by downwards travel of awning,
roller shutter, or venetian blind!
The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the
system.
2. Use the hand-held transmitter to bring the blind to the
centre position.
3. Moisten the rain sensor.
The set rain value is reached
or exceeded.
Red alarm LED shines. The
blind travels up immediately.
Stop moistening the rain sen-
sor. The set rain value is now
undercut.
The red alarm LED
fl
ashes for
15 seconds.
You can repeat the operation as often as you want within 5
minutes.
Deleting a programmed sensor
(Not possible in the Function position).
Press the UP and DOWN buttons simultaneously for at least
3 seconds.
The green operating LED goes out brie
fl
y.
The device is now deleted from all receivers within range.
Maintenance
The device must be freely accessible and must not be
overgrown by vegetation.
The device is maintenance-free, however the cover must be
cleaned from time to time using a moist cloth.
CAUTION!
Caution - Very Hot! Risk of burns if touched!
The rain sensor is hot when operating!
Do not touch the rain sensor!
Disposal
After
fi
nal utilisation, dispose of the device pursuant to the
applicable regulations.
Troubleshooting
Fault
Cause
Remedy
The blind
travels up
automatically in
manual mode
The wind or rain alarm is
active.
Wait until the delay
time has elapsed (15
minutes).
The rain sensor is dirty.
Clean the rain
sensor.
Poor radio connection
Change the position
of the device.
Voltage supply is inter-
rupted.
Check the voltage.
Maintenance