background image

 
 

 ISO

zertifizie rt

 

Vacuum lifter EP 800 / 600 / 400 / 300 / 150 - Operating instructions 

 

 

File: 

 

 

D:\\Bedienungsanleitungen\Englisch\Vakuumheber EP 800 600 400 300 150 

Revision/ Erstellt am: 

4/ 12.10.2001

 

Page: 5 of 11 

 
 
 

 

4.5  Machine identification plate  

 
The identification plate informs about the origin, identity as well as year of 
construction and, if necessary, about the maximum carrying capacity. 
 
By the supply please compare the identification plate with the data on the 
first side of the operating instructions. If the data differ from each other, 
please contact immediately the dealer or the manufacturer. 
 

 

 

4.6  Technical and structural data 

 

4.6.1  Vacuum lifter EP 150 

 

Total height [cm] 

19 cm 

Max. Load capacity [kg] 

150 kg 

Total width [cm] 

55 cm 

Net weight [kg] 

13 kg 

Total length [cm] 

33 cm 

Suction area [cm x cm] 

50 cm x 11 cm 

 

4.6.2  Vacuum lifter EP 300 

 

Total height [cm] 

19 cm 

Max. Load capacity [kg] 

300 kg 

Total width [cm] 

55 cm 

Net weight [kg] 

14 kg 

Total length [cm] 

33 cm 

Suction area [cm x cm] 

54 cm x 15 cm 

 

4.6.3  Vacuum lifter EP 400 

 

Total height [cm] 

19 cm 

Max. Load capacity [kg] 

400 kg 

Total width [cm] 

51 cm 

Net weight [kg] 

19 kg 

Total length [cm] 

40 cm 

Suction area [

 cm] 

 40 cm 

 

4.6.4  Vacuum lifter EP 600 

 

Total height [cm] 

19 cm 

Max. Load capacity [kg] 

600 kg 

Total width [cm] 

61 cm 

Net weight [kg] 

22 kg 

Total length [cm] 

40 cm 

Suction area [cm x cm] 

60 cm x 25 cm 

 

4.6.5  Vacuum lifter EP 800 

 

Total height [cm] 

24 cm 

Max. Load capacity [kg] 

800 kg (lying stone slab) 

Total width [cm] 

35 cm 

Net weight [kg] 

45 kg 

Total length [cm] 

75 cm 

Suction area [cm x cm] 

70 cm x 30 cm 

 

4.7  Supply and connections 

 

Battery charger - Electrical supply  

230V / 50Hz 

Compressed air supply (optional) 

Filtered and lubricated with pressure of max. 8,0 bar 

 
 

5  Assembly 

 
Please read carefully the information in the chapter “Assembly” and follow it precisely. The manufacturer or the company WEHA-Ludwig 
Werwein GmbH will not be liable for any damage due to incorrect assembly. 
 
On receipt, check the supplied commodity for any damage during transportation and packing. Advise the manufacturer/agent 
immediately about any damage! 
 

 

The dealer/manufacturer are not liable 

 for any defects caused by incorrect assembly and incorrect application!  

 

 

Please follow precisely the safety regulations in chapter 4.3 ! 

Summary of Contents for EP 150

Page 1: ...ning instructions 3 3 1 Warning instructions on the Vacuum lifter EP 3 3 2 Symbols in the operating instructions 3 4 Regulations for the use of the Vacuum lifter EP 3 4 1 Field of application of the V...

Page 2: ...uestions and orders please contact the WEHA Ludwig Werwein GmbH or directly the manufacturer In Germany In Austria WEHA Ludwig Werwein GmbH WEHA Steinbearbeitungsmaschi nenvertriebsgesellschaft m b H...

Page 3: ...to read and follow it with particular attention Obligation to recycle waste materials into the production process to help safeguard the natural resources and save the environment Marking of switches a...

Page 4: ...e of the stone slab must be smooth ground in the contact surface of the vacuum lifters EP The face of the stone slab must be an even plane Make sure that the Vacuum lifter EP is placed in the middle o...

Page 5: ...0 Total height cm 19 cm Max Load capacity kg 400 kg Total width cm 51 cm Net weight kg 19 kg Total length cm 40 cm Suction area cm 40 cm 4 6 4 Vacuum lifter EP 600 Total height cm 19 cm Max Load capac...

Page 6: ...care that any sharp edged articles do not damage the protective layer of the metal parts The dealer and or manufacturer is not liable for any defects caused by incorrect assembly Please follow precise...

Page 7: ...e eye F2 to the lifting equipment Make sure that the lifting tackle and the lifting equipment have the necessary load capacity to carry and transport the gross lifting weight Don t exceed the admissib...

Page 8: ...control device You can operate the hand slide valve by means of remote control device comprising the receiver A3 the remote control device B3 and the control valve C3 Before putting into operation ma...

Page 9: ...following activities by a person with the appropriate training The manufacturer is not liable for any damage due to neglect of these instructions Please follow precisely the safety regulations in cha...

Page 10: ...ion plate for EP 400 vulcanized Art No VD080215 1 1 Suction plate for EP 600 vulcanized Art No 8020823 1 1 Suction plate for EP 800 vulcanized Art No VD080120 2 1 Pneumatic cylinder for EP 150 EP 300...

Page 11: ...vision Erstellt am 4 12 10 2001 Page 11 of 11 39 1 Warning device 40 1 Remote control device optional 41 1 Pneumatic injector valve optional Art No 8020800 Vacuum lifter EP Vacuum lifter EP 150 Art No...

Page 12: ......

Reviews: