6.3 Operating the additional assembly groups (optional)
6.3.1 Vacuum lifter EP with remote-control device
For the additional safety regulations see paragraph 4.3.
Attention danger!
Take care that the remote-control device can not be accidentally released!
Attention danger!
Ensure that no strong electro-magnetic fields are in the proximity, e.g. mobile phones, electrified rails,
power lines or similar!
•
The vacuum lifter EP with remote-control device should not be used near strong electro-magnetic fields. Do not keep in close
proximity or do not use any mobile phone whilst in operation.
Picture 6.3
– Remote-control device
•
You can operate the hand slide valve by means of
remote-control device, comprising the receiver [A3],
the remote-control device [B3] and the control valve
[C3].
•
Before putting into operation make sure that the 9V-
Block-Battery of the remote-control device has
enough power.
Picture 6.4
- Remote-control device
•
Instead of the instruction „Turn the blue ring of the
hand slide valve [A2] to the right [Picture 6.2]“
[Paragraph 6.2] push the gray button [B4] of the
remote-control device [A4].
•
The remote-control device [A4] must show with the
front side (the side with the red warning light [D4]) to
the receiver [E4]. If the remote-control device [A4] is
used in the right way, both red warning devices [D4]
light.
•
Now you must operate the pneumatic cylinder again,
as explained in paragraph 6.2 from point 8.
•
After setting down and securing the stone slab,
press the red button [C4] of the remote-control
device. The vacuum chamber will be now
ventilated and the vacuum safety tank retain the
vacuum.
B3
C3
A3
C4
D4
A4
B4
E4