background image

 

WEH GmbH Gas Technology  |  Josef-Henle-Str. 1  |  89257 Illertissen  

Dok.-Nr. 0047004_001.doc 

Page 7 of 9 

 

 

Maintenance of the filter element 

Type

 

TSF5

 

 

MAINTENANCE INSTRUCTION 

 

5 |

 

Clean the thread with a

 

clean, lint-free cloth

.  

 

          

 

 

10  Maintenance of Pos.3 

The maintenance intervals have to be determined by yourself depending on the operating time and the 
impurities in the medium. 
We recommend to put the filter on a lamp to detect those impurities.  
Even very fine impurities between the single wire windings become visible.  
Different procedures can be applied for cleaning the wire filter. 
 
 

 

 

10.1  Cleaning procedure for coarse impurities

 

  Blow out the impurities from the inner side of the wire filter with compressed air contrary to the 

flow direction.  

 

          

 

 

Flow direction 

Summary of Contents for TSF5

Page 1: ...MAINTENANCE INSTRUCTION Maintenance instruction Type TSF5 CNG Filter also valid for versions with ferrule fitting FUTURE TECHNOLOGY TODAY 0047004_001 doc Date 07 10...

Page 2: ...absolutely free of dirt and dust Smallest dirt particle may cause leakage Please strictly observe the correct mounting direction and order of the sealing components Sealing components may not get in c...

Page 3: ...9257 Illertissen Dok Nr 0047004_001 doc Page 3 of 9 General information Type TSF5 MAINTENANCE INSTRUCTION 3 Assembly tools Part No 82284 Part No 61461 Part No 59575 A F 30 Part No 101969 Part No 70139...

Page 4: ...WEH GmbH Gas Technology Josef Henle Str 1 89257 Illertissen Dok Nr 0047004_001 doc Page 4 of 9 General information Type TSF5 MAINTENANCE INSTRUCTION Part No 63416...

Page 5: ...UNG 4 Lubricants Part No E99 4 5 Adhesives Part No 90160 6 Cleaning agents Part No E99 9 7 Part list Pos No Quantity Part No Description 1 1 83715 Valve housing 2 1 83716 Valve lower part 3 1 31704 Fi...

Page 6: ...RUCTION 9 Disassembly 1 Unscrew and remove Pos 2 using Part No 47475 Part No 59758 and Part No 70139 remove Pos 3 2 Remove Pos 4 and 5 carefully out of the recess using part no 101969 3 Spray the thre...

Page 7: ...determined by yourself depending on the operating time and the impurities in the medium We recommend to put the filter on a lamp to detect those impurities Even very fine impurities between the singl...

Page 8: ...th compressed air to clean it Requirements on cleaning agents 1 The cleaning agent may not contain ammonia as the base body of the wire filter is made out of brass 2 Do not use aggressive substances b...

Page 9: ...f Pos 1 Take care of installation position 3 Place Pos 3 in Pos 1 4 Adhere Pos 2 with Pos 1 using part no 90160 Apply adhesive all around the first thread of Pos 2 Screw Pos 2 with Pos 1 using part no...