Î
Before installation, check if the counterparts are designed to withstand the assembly
data (see
Chapter 7.2 Installing the filter
) that WEH determined for this WEH
®
Product.
Note:
The indicated assembly data (tightening torques, assembly turns etc.) are values
that apply only to the components delivered by WEH.
7�2
Installing the filter
Please note:
Subsequent mentions of descriptions and position numbers refer to
Chapter 3. Product overview / product description on page 10
Î
Unscrew the protection caps from the ports.
Î
When mounting the filter, hold against the wrench flats with an open-ended wrench.
Î
Install the filter into your system at ports ‘B1’ and ‘B2’. Place the ports of the media
line straight and screw them on pressure-tight without tilting.
Attention:
Please note the flow direction marked.
Tightening torque 60 Nm +10% (UNF 1 3/8“-12 male thread)
8. COMMISSIONING
- Before commissioning, check the WEH
®
Product for leak tightness.
Î
Apply the operating pressure slowly to the WEH
®
Product slowly.
Î
Use a foaming leak detection agent to check the WEH
®
Product and connection to the
product for leak tightness. The test points must be sealed tight without any bubbles.
Caution:
Observe the technical data in
and all appropriate technical stan-
dards and applicable legal requirements.
Attention:
Do not use a leak detection spray that contains ammonia, since this could
cause
corrosion of the product.
MD-10012-L51-R1.1.0-03
Page 16
Operating instructions
AE
Summary of Contents for TSF4
Page 2: ......