62
of
68
TECHNICIANS manual
14.7.12 Wiring diagram cod. WY18090051 - WY18090052
SL
NE
BL
NE
MA
MA
MA
RO
BL
VE
VE
VE
VE
CV3
CV2
CV1
CN2
F2
CN5
TRF1
CN1
CN4
JP3
JP7
JP4
JP6
IC9
JP8
JP16
JP1
JP17
JP18
JP2
JP9
JP15
CN12
CN11
JP5
CN10
RL9
F1
CN14
CN3
JP10
GND
RX
+5V
TX
CN16
CN15
CN17
RL8
RL6
RL4
RL3
RL2
CN13
RL1
JP12
JP14
MB
VE
CN18
VE
BL
VE
BL
VE
BL
RO
RO
RO
RO
RO
RO
BI
RO
CN20
CN19
RO
BL
CT
SCT
IST
LA
LST
PR
SA
RE
400V
TLR
IG
R
S
T
N
MA BL
NE
GR
CAB
MA
BL
PL
APL
CPL
EVCAP
EVV
EVA
CAL
IM1
IM2
IM3
EVT
EV1
EVC
EV3
EV2
MP
GV
FP1
FP2
O
O
O
1
3
5
13
2
4
6
14
L1
L2
L3
NO
T1
T2
T3
NO
A1
A2
APL
Milk pump supply
BI
White
BL
Blue
CAB
Power cable
CAL
Boiler
CN1
Supply connector
CN2
Low voltage connector
CN3
Link connector display diag.
CN4
Serial transmission connector
CN5
Programm. connector ISP
CN10
Push button panel connector GR1
CN11
Push button panel connector GR2
CN12
Push button panel connector GR3
CN13
Autosteamer/capp. connector
CN14
Service outputs connector
CN16
NTC steam connector
CN17
NTC boiler connector
CN18
NTC cup heater connector
CPL
Milk pump control
CT
Supply connector
CV1
Volumetric counter GR1
CV2
Volumetric counter GR2
CV3
Volumetric counter GR3
EV1
Solenoid valve GR1
EV2
Solenoid valve GR2
EV3
Solenoid valve GR3
EVA
Air solenoid valve
EVC
Boiler filling solenoid valve
EVCAP
Cappuc. mak. solenoid valve
EVT
Tea solenoid valve
EVV
Steam solenoid valve
F1
Inlet fuse (6.3A)
F2
Motor pump fuse (500mA)
FP1(*)
UL (OPD) Motor pump fuse
FP2(*)
UL (OPD) Fuse for 230V
GR
Grey
GV
Yellow-green
IC9
Microprocessor
IG
Main switch
IM1
GR1 manual switch
IM2
GR2 manual switch
IM3
GR3 manual switch
IST
Cup heater switch
LA
Indicator light
MA
Brown
MP
Motor pump
NE
Black
PL
Milk pump
PR
Pressure switch
RE
Resistance
RO
Red
SA
Resistance safety device
SCT
Cup heater heating element
TLR
Remote switch
TRF1
Transformer
VE
Green
(*) Fuses for UL versions with plug with
a greater capacity than 30A
JUMPER
INSERTED
NOT INSERTED
JP1
Serial transmission enabled
Serial transmission disabled
JP2
Not managed
Not managed
JP3
Programming key connection
JP4
Boiler filling with pump
Boiler filling without pump
JP5
Tea key connection
JP6
Tea dispensing with pump
Tea dispensing without pump
JP7
Continuous function disabled
Continuous function enabled
JP8
Dose count enabled
Dose count disabled
JP9
Credit/Debit enabled
Credit/Debit disabled
JUMPER
INSERTED
NOT INSERTED
JP10
Tea key 2 connection
JP12
Not managed
Not managed
JP14
Not managed
Not managed
JP15
Display function keys enabled Display function keys disabled
JP16
6-key push button panel enabled 4-key push button panel enabled
JP17
Boiler t°check with external pressure switch (always on)
JP18
Heat.temp./press. management always ON
JP22
Programming via Indar
Summary of Contents for 1GR Series