Startup
ECW500 | 67
LTOC High level: __________________
LTOC Low level: __________________
LTOC Time to actuation: ___________________
10.4.5
Configuring the Protections
Protection of feedback loss PFL ON/OFF: _____________
Protection of feedback loss PFL changes to MECC mode: _____________
Protection of feedback loss PFL voltage balanced: _____________
Protection of feedback loss PFL voltage unbalanced: _____________
Protection of feedback loss PFL time to actuate: _____________
Protection of excitation overvoltage PEOV ON/OFF: _____________
Protection of excitation overvoltage PEOV limit level: _____________
Protection of excitation overvoltage PEOV time to actuate: _____________
Protection of excitation overcurrent PEOC ON/OFF: _____________
Protection of excitation overcurrent PEOC limit level: _____________
Protection of excitation overcurrent PEOC time to actuate: _____________
Protection of terminal undervoltage PTUV ON/OFF: ________________
Protection of terminal undervoltage PTUV limit level: ________________
Protection of terminal undervoltage PTUV time to actuate: ________________
Protection of terminal undervoltage PTOV ON/OF: ________________
Protection of terminal overvoltage PTOV limit level: ________________
Protection of terminal overvoltage PTOV time to actuate: ________________
Protection of the rotating diodes PED ON/OFF: ________________
Protection of the rotating diodes PED time to actuate: ________________
Protection of excitation loss PEL ON/OFF: ______________
Protection of excitation loss PEL time for warning: ______________
Protection of the PWM maximum power module: ______________
Protection of the PWM minimum power module: ______________
Protection of the power module by phase loss enable/disable: _____________
Protection of the power module, maximum temperature of the module: ______________
Protection of the power module, time for warning of maximum temperature: ______________
Protection of the power module enable/disable shutting down: ______________
NOTE!
The adjustments of the protection limits of rotating diodes must be done during the first machine
excitation.
10.5
TESTS ON THE OFFLINE MODES
After the configuration of the regulator is done, it must be made the first power-up applying the excitation to the
synchronous machine with no load and disconnected from the line or other machines. The main objective is
detecting wrong connections and bad configurations.
10.5.1
Turning On and Off the Regulator with Machine Spinning
1. With the regulator OFF, check if the "Automatic" and "Manual" commands are toggling the operating mode of
the regulator via HMI, via supervisory software or via specific keys on the digital inputs.
Result: _____________________________________________________________________________
2. With the machine spinning, check the remanent voltage measurement, the terminal current and the frequency
on the HMI, or supervisory software.
Result: _____________________________________________________________________________
3. Put the regulator in the manual mode (MECC) and set the excitation current reference to 20% of the rated
excitation current value. Enable the regulator and wait for the ramp to reach the reference setting.
Summary of Contents for ECW500