Errors, Warnings and Events
ECW500 | 13
Table 2.2
Warning list
WR000
Digital input did not receive complementary command
WR001
Problem on the configuration of the digital inputs
WR002
Incorrect command of the parallel or online digital inputs
WR003
Parallel command received with the ECW500 off
WR004
No online mode configured, but online command received
WR005
Increment and decrement digital inputs simultaneously triggered
WR006
Calibration executed with the ECW500 on
WR007
Excitation disconnected
WR008
Phase loss at the power terminals
WR009
Internal overheating
WR010
Terminal overvoltage
WR011
Terminal undervoltage
WR012
Excitation overvoltage
WR013
Excitation overcurrent
WR014
Underfrequency
WR015
Received command to reset parameters with the ECW500 enabled
WR016
Alarm reset is missing to execute the command
WR017
Analog input cable 4 to 20 mA broken
WR018
Autotuning execution fail
WR019
MAC address problem
WR020 WR034
Reserved
WR035
Feedback loss
WR036
Rotating diodes fault
WR037
PxQ curve configuration problem
WR038
Anybus offline
WR039
Anybus fault
2.3
EVENTS
Events, on the other hand, are normal occurrences and not harmful to the system operation, as a mode
transition, a received command and others.
Events are not indicated on the HMI, and only recorded in the event list.
Table 2.3
Event list
EV000
Excitation OFF
EV001
Excitation ON
EV002
Calibration of the analog input of +/-10 Vdc executed
EV003
Command of alarm reset received
EV004
Changed to MECC mode
EV005
LEOC limiter actuating
EV006
LEOC limiter stopped actuating
EV007
LUF limiter actuating
EV008
LUF limiter stopped actuating
EV009
Received command for resetting parameters to factory default
EV010
Calibration of the measurement of the excitation current executed
EV011
LTOC limiter actuating
EV012
LTOC limiter stopped actuating
EV013
Changed to MTVC mode
EV014
LEUC limiter actuating
EV015
LEUC limiter stopped actuating
EV016
Changed to online mode
EV017
Changed to parallel mode
EV018
Autotuning started
EV019
Autotuning finished with successful
EV020
Autotuning canceled by the user
EV021
Autotuning timeout
NOTE!
When a warning or error occurs, the HMI will periodically display the message "There are some
warnings or errors" until an alarm reset is executed.
You can set how long this message appears and how long it is hidden in the HMI Configuration
screen.